InsTallInG sTaTIon modules.....................................................
ACC expands in 6-station increments with intelligent output modules, requiring no tools to install and only a screwdriver
for station wiring connections. The base configuration is 12 stations (two 6-station modules installed) with a maximum
station capacity in a metal wall cabinet of 42 stations (7 total output modules x 6 stations each).
ACC can be expanded at any time with either of the following types of modules:
1. ACM600, 6-station output module with surge suppression and diagnostic LEDs
2. AGM600, 6-station output module with heavy-duty surge suppression and diagnostic LEDs
These two types of modules may be mixed within the same installation if desired.
1. To install expansion modules, turn the dial to the
Runposition.
2. Open the inner facepack door, and locate the module
lock. Slide the module lock to the Power Off
position.
3. Flip up the upper deck cover. Slide the modules up,
into the next available position, viewed from left to
right. Do not skip slots by leaving them empty.
4. Install a module by aligning it firmly in the lower
portion of the next available slot and sliding straight
up until it clicks into place. Once module is in place,
slide power bar to the "Power On" position. The
first two lights of the bottom and top row of each
module installed will light up red for 1 second,
indicating proper contact and the new module has
been recognized. The red lights will then turn off, in
sequence, from left to right across the modules that
are installed.
5. The silver contact on the back of the controller
cabinet must engage a mating slot in the back of the
expansion module. Do not tip or force the module
into place. Slide straight up, from the bottom of
the slot.
6. While at the Run dial position, press the Information
button. The current station size will be shown, and
should include any new modules you have added.
US PATIENT NO 6,842,667 B2
ET FLOW SEN4 SEN3 SEN2 SEN1
ET FLOW SEN4 SEN3 SEN2 SEN1 COM
P/M1 P/M2
24
VAC
1 2 3
4 5 6
7 8 9
10 11 12
13 14 15
16 17 18
19 20 21
22 23 24
25 26 27
28 29 30
31 32 33
34 35 36
3837 39
40 41 42
OUTPUT MODULES (ACM600, AGM600)
A. Station Output Screw Terminals Connect no more
than two solenoids each.
B. Station Status LEDs Green for station activity, Red
for fault or short
C. Locking lugs For module lock
D. Gold plated electrical contacts Lower rear of
module
E. Additional surge components, AGM versions
Visible through module
Slide ADM99 in
first 3 slots
Upper Deck cover
ADM99 Decoder
Output Module
A
B
C
D
E
ACM600
6-station output
module
AGM600
6-station output module with
heavy duty surge protection
Station Modules
Decoder Output Module
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC in the language / languages: English as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC

Hunter ACC User Manual - German - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info