685907
12
Zoom out
Zoom in
Previous page
1/100
Next page
5
The ACC can operate with either 120 VAC or 230 VAC power,
depending on how the incoming AC wires are connected.
Supply wires must be 14 AWG (2 mm) or larger.
The ACC is prewired for 120V operation but can easily be
changed to 230V.
Consult or hire a licensed electrician for these connections
as required.
Turn AC power off at the source, and verify that it is
off.
Remove the wiring compartment screws and the
wiring compartment door.
Strip approximately ½" (13 mm) of insulation from the
end of each of the AC power wires, and route into the
wiring compartment through the conduit.
Locate the white plastic terminal block, and wire
according to the following diagrams.
For 120V~ operation, connect the incoming black power
wire (hot) to align in the wiring block with the black wire
lead from the transformer.
Insert the incoming black wire lead into the hole opposite
the black transformer wire and tighten screw securely.
Connect the incoming neutral (white) wire to align with the
blue lead from the transformer.
Cap off the brown (230 VAC) wire if applying 120V and not
using a wiring block. The brown wire will be hot and have a
230V charge.
ACC Transformer
Black (120 VAC) U.S.White (Neutral) U.S.
or Blue (Neutral) Int'l
Brown (230 VAC)Blue (Neutral)
Black (120 VAC)
The green, or green-and-yellow safety ground
may not be required or permitted with this
floating ground, double-insulated transformer.
If desired and permitted, connect it to the earth
ground lug on the controller. Install a conduit
junction T-box below the supplied junction box
in the controller, and route the safety ground
out of the T to the earth ground lug of the
controller.
Tighten screw and replace cover.
For 230V~ operation, connect the incoming power
wire (hot, brown in many wiring standards) to align
in the wiring block with the brown wire lead from the
transformer. Connect the incoming Neutral (blue in some
international standards) wire to align with the blue lead
from the transformer. Tighten screws and replace cover.
Apply AC~ power and test. Refer to Earth Ground and
Station Wiring sections for additional connections.
ACC Transformer
Blue (Neutral)
Brown (230 VAC)Blue (Neutral)
Black (120 VAC)
Brown (230 VAC)
ConneCTInG aC maIn poWer, Wall mounT CabIneT .................
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC in the language / languages: English as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC

Hunter ACC User Manual - German - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info