685908
39
Zoom out
Zoom in
Previous page
1/52
Next page
Built on Innovation
®
39
Flow Operations
STATION LEVEL ALARMS
If ow does drop to near zero when the Flow Zone is paused,
the controller then begins running the stations that were
running at the time of the alarm, one by one, to test which
station(s) are causing the high ow conditions. The controller
will mark failed stations in the logs, and continue irrigating
with stations that pass the individual ow tests.
FLOW ZONE OR MAINSAFE ALARMS
If ow does not drop substantially during the diagnostic pause
period, the controller determines there is a Mainline Overow,
and will not resume irrigating or perform further diagnostics.
It will remain shut down for the period specied in the Alarm
Clear Delay setting on the Flow Zones screen.
When ow alarms are detected at the Flow Zone or MainSafe
level, they can be cleared from the Flow menu, Clear Flow
Alarms. A shortcut key is also available to Clear Flow Alarms
when these conditions are detected, aer View Messages has
been selected.
If the actual ow exceeds the Maximum Flow allowance
for the Flow Zone, and continues for the time set in the
Alarm Delay, the Flow Zone alarms and shuts down without
further diagnostics. The same applies to MainSafe zones, if
applicable. The controller assumes the overow condition is
the result of a mainline failure, above the station level.
If ow exceeds any Unscheduled Flow allowance when no
stations are supposed to be running, and continues for the
time set in the Alarm Delay, the Flow Zone and/or MainSafe
zone will also be shut down.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC-2 in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC-2

Hunter ACC-2 Quick start guide - German - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info