The pump supplies a
limited amount of
water or the pump
does not pump
water, and the
motor is running
Pump full of air Unplug from the electricity supply and
disconnect outlet hose, submerge in
water and allow air to escape, re-connect
hose and power
Obstructed inlet Follow cleaning instructions detailed in
maintenance section (Figs 8 &9)
Obstructed pipe/outlet Remove obstructions in inlet hose or kinks
and clean out filter
Worn impeller Contact Hozelock customer services for
assistance
The pump works
only intermittently
Solid particles prevent the
free rotation of the impeller
Clean inlet and impeller
(Figs 8 & 9)
The temperature of the fluid
is too high
Only use with fluids below 35ºC
Faulty motor Contact Hozelock customer services for
assistance
Water is leaking
from the outlet of
the pump
Inlet assembly not tight
enough
Tighten
Float switch is preventing
pump turning on
The pump will only work when the float
switch is in the upright position, ensure
that is is able to reach the vertical
position
Troubleshooting
Problem Possible Cause Remedy
The pump does not
pump water and the
motor is not running
No electricity Check that the electricity supply is turned
on and that the pump is correctly plugged
in
Plug inserted incorrectly
Circuit breaker is tripped Reset electricity supply.
If the circuit breaker trips once more
contact a specialised electrician
Damaged motor Contact Hozelock customer services for
assistance
Pump has overheated Pump contains thermal protection - check
if pump case is hot, and if so, allow to
cool
Blocked impeller Unplug from the electricity supply and
remove possible obstructions from the
impeller (Figs 8 & 9)
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hozelock 7825 Flood Pump at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hozelock 7825 Flood Pump in the language / languages: All languages as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info