Figure 34
Setting the function of the option relay
Select menu 5 by pressing the PRG button.
The flashing figure displayed indicates the
set function of the option relay, which can be
altered using the OPEN or CLOSE buttons:
Display Function
0 Relay OFF
(factory setting)
1 2s warning phase before every
door movement: flashing
2 2s warning phase before every
door movement: permanent
light (e.g. revolving beacon)
3 Relay picks up with the opera
tor. Lighting (external light)
Change to menu 0 by pressing the PRG
button.
Figure 35
Correcting the closing force
In menu 6 (factory setting = 0) the automatic
power limit for closing the door can be
altered to a less sensitive setting. This is only
necessary for doors which run extremely
unevenly. An unneces
sarily high setting should not be selected.
If the closing force is set too high, this can
result in damage to property or injury to per-
sons.
Change to menu 0 by pressing the PRG
button.
Figure 36
Correcting the belt relief
In menu 7 the automatic belt relief at the
CLOSE travel limit can be influenced:
Display Function
0 Automatic relief
(faxtory setting)
1 No relief
(observe belt tension!)
2 Always short relief
3 Always medium relief
4 Always long relief
Change to menu 0 by pressing the PRG
button.
20