Figure 32
Setting the automatic timer (for safety
reasons we recommend fitting a photo-
cell and/or closing edge safety device)
Select menu 3 by pressing the PRG button.
The flashing figure displayed indicates the
set waiting time of the door in the OPEN
position, which can be altered using the
OPEN or CLOSE buttons.
Display Waiting time
0 No automatic timer
(factory setting)
1 10s
2 20s
3 30s
4 40s
5 50s
6 60s
When the automatic timer is active, the ope-
rator lighting flashes two seconds before the
start of travel. If during this time the remote
control is operated, the set waiting time
starts afresh. Change to menu 0 by pressing
the PRG button.
Figure 33
Setting the photocell/closing edge
safety device
Select menu 4 by pressing the PRG button.
The flashing figure displayed indicates the
following settings which can be altered using
the OPEN or CLOSE buttons:
LS = photocell
SKS = closing edge safety device
Change to menu 0 by pressing the PRG
button.
19
ENGLISH
Terminals: 71 18 19 18
Display LS signal LS self-testing SKS signal SKS self-testing
0 no no no no
(factory setting)
1 yes no no no
2 yes yes no no
3 no no yes no
4 yes no yes no
5 yes yes yes no
6 no no yes yes
7 yes no yes yes
8 yes yes yes yes