11 Warranty Conditions
Warranty
We shall be exempt from our warranty obligations and
product liability in the event that the customer carries out his
own structural alterations or undertakes improper installation
work or arranges for same to be carried out by others without
our prior approval and contrary to the fitting guidelines we
have provided. Moreover, we shall accept no responsibility for
the inadvertent or negligent use of the operator nor improper
maintenance of the operator and the accessories, as well as
for improper maintenance of the door and its counterbalance.
Batteries and light bulbs are also not covered by the warranty.
Warranty period
In addition to the statutory warranty provided by the dealer in
the purchase contract, we grant the following warranty from
the date of purchase:
• 4 years or
• 5 years (depending on operator type)
• 2 years on radio equipment and accessories
Claims made under the warranty do not extend the warranty
period. For replacement parts and repairs the warranty period
is six months or at least the remainder of the warranty period.
Prerequisites
A claim under this warranty is only valid for the country in
which the equipment was bought. The product must have
been purchased through our authorised distribution channels.
A claim under this warranty exists only for damage to the
object of the contract itself. Reimbursement of expenditure
for dismantling and fitting, testing of corresponding parts, as
well as demands for lost profits and compensation for
damages, are excluded from the warranty.
The receipt of purchase substantiates your right to claim
under the warranty.
Performance
For the duration of the warranty we shall eliminate any
product defects that are proven to be attributable to a
material or manufacturing fault. We pledge to replace free of
charge and at our discretion the defective goods with non-
defective goods, to carry out repairs, or to grant a price
reduction.
Damages caused by the following are excluded:
• improper fitting and connection
• improper initial start-up and operation
• external factors such as fire, water, abnormal
environmental conditions
• mechanical damage caused by accidents, falls, impacts
• negligent or intentional destruction
• normal wear or deficient maintenance
• repairs conducted by unqualified persons
• use of non-original parts
• removal or defacing of the product number
Replaced parts become the property of the manufacturer.
12 Excerpt from the Declaration of
Incorporation
(as defined in EC Machinery Directive 2006/42/EC for
incorporation of partly completed machinery according to
annex II, part B)
The product described on the reverse side has been
developed, constructed and produced in accordance with the
following directives:
• EC Machinery Directive 2006/42EC
• EC Construction Products Directive 89/106/EEC
• EC Low-Voltage Directive 2006/95/EC
• EC Electromagnetic Compatibility Directive 2004/108/EC
Applied and consulted standards and specifications:
• ENISO 13849-1, PL “c”, Cat.2
Safety of machinery – Safety-related parts of control
systems – Part 1: General principles
• EN60335-1 / 2, when applicable
Safety of electrical appliances / Operators for doors
• EN61000-6-3
Electromagnetic compatibility – Electromagnetic
radiation
• EN61000-6-2
Electromagnetic compatibility – Interference immunity
Partly completed machinery as defined in the EC Directive
2006/42/EC is only intended to be incorporated into or
assembled with other machinery or other partly completed
machinery or equipment, thereby forming machinery to which
this directive applies.
This is why this product must only be put into operation after
it has been determined that the entire machine / system in
which it will be installed corresponds with the guidelines of
the EC directive mentioned above.
Any modification made to this product without our express
permission and approval shall render this declaration null and
void.
13 Technical Data
Mains voltage 230 / 240 V, 50 / 60 Hz,
Stand-by Approx. 6W
Mains voltage type Y
Protection category Only for dry rooms
Temperature range – 20 °C to + 60 °C
Automatic safety
cut-out
Is automatically taught in for both
directions separately.
End-of-travel
position cut-out /
Force limit
• Self-learning
• Wear-free, as it is designed
without mechanical switches
• Additionally integrated run time
limit of approx. 45 s
• Automatic safety cut-out,
readjusting at every door run.
Rated load See data label
Pull and push force See data label
Motor Direct current motor with hall sensor
Transformer with thermal protection
Connection
technology
• Simple screw terminal
• Max. 1.5mm
2
• For internal and external
buttons with impulse operation
32
TR10L006-C RE / 11.2013
ENGLISH
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hormann Liftronic 700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hormann Liftronic 700 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 12,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info