LED Flashes constantly
Cause The operator is in the Holiday function,
the radio is locked by an internal push
button (this is only a message and not
a malfunction).
Remedy Press the locking key on the internal
push button.
LED Flashes 2×
Cause A connected photocell was interrupted
or actuated. A safety reversal may
have occurred.
Remedy Eliminate the obstruction cause
and / or check the photocell and
replace if necessary.
Acknowled-
gement
Renewed impulse entry by means of
an external button, a hand transmitter
button or the Tbutton.
In the OPEN end-of-travel position a
closing run will take place, otherwise
an opening run.
LED Flashes 3×
Cause The CLOSE force limit has been
activated; a safety reversal took place.
Remedy Remove the obstruction. If the safety
reversal took place for no apparent
reason, check the door mechanism or
the tension of the toothed belt. If
necessary, delete the door data
(seesection9) and teach it in again
(seesection4.2) or adjust the tension
of the toothed belt (seesection7.1).
Acknowled-
gement
Renewed impulse entry by means of
an external button, a hand transmitter
button or the Tbutton.
An opening run will take place.
LED Flashes 5×
Cause The OPEN force limit has been
activated. The door was stopped
during an opening run.
Remedy Remove the obstruction. If the door
stopped before the OPEN end-of-
travel position for no apparent reason,
check the door mechanism or the
tension of the toothed belt.
If necessary, delete the door data
(seesection9) and teach it in again
(seesection4.2) or adjust the tension
of the toothed belt (seesection7.1).
Acknowled-
gement
Renewed impulse entry by means of
an external button, a hand transmitter
button or the Tbutton.
A closing run will take place.
LED Flashes 6×
Cause Operator error / malfunction in operator
system
Remedy If necessary, delete the door data
(seesection9) and teach it in again
(seesection4.2). If the operator error
occurs again, replace the operator.
Acknowled-
gement
Renewed impulse entry by means of
an external button, a hand transmitter
button or the Tbutton.
An opening run will take place (OPEN
reference run).
LED Flashes 7×
Cause The operator has not been taught in
yet (this is only a message and not a
malfunction).
Remedy /
acknowled-
gement
Trigger the learning run by an external
button, a hand transmitter button or
the Tbutton.
LED Flashes 8×
Cause The operator requires an OPEN
reference run (this is only a message
and not a malfunction).
Remedy /
acknowled-
gement
Trigger the OPEN reference run by an
external button, a hand transmitter
button or the Tbutton.
Note This is the normal status after a power
failure if no door data is present or has
been deleted and / or the last door
position is not sufficiently known.
9 Deleting Door Data
See figure19
If it is necessary to teach in again, the door data can be
deleted as follows:
1. Disconnect the mains plug.
2. Press and hold the Tbutton on the operator cover.
3. Connect the mains plug and keep the Tbutton pushed
until the operator light flashes once.
It can now be taught in again. This is signalled by the red LED
flashing 8 times.
NOTE:
You can read more about operator light messages (repeated
flashing when the mains plug is plugged in) in section8.1.
10 Dismantling and Disposal
NOTE:
When disassembling, observe the applicable regulations
regarding occupational safety.
Have a specialist dismantle the garage door operator in the
reverse order of these instructions and dispose of it properly.
Contact your supplier for this purpose.
TR10L006-C RE / 11.2013 31
ENGLISH
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hormann Liftronic 700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hormann Liftronic 700 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 12,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info