Part 2: For the operator
2.2 CLEANING (Fig. 10)
2.2.a General information
Strict compliance with the maintenance instructions in this
section will keep your machine in a good working condition
and will notably reduce the need for repairs.
ATTENTION
If any machine component becomes faulty, FIRST CHECK
that all the instructions given in the previous paragraphs
have been complied with during use.
Repairs must be carried out immediately, as soon as the
fault occurs. This will prevent the trouble from becoming
worse and damaging other parts.
ATTENTION
Daily operations to carry out when work has ended, with
the machine OFF , the main circuit-breaker disconnected,
the water cocks off and the washing tub empty.
1. Thoroughly clean the inside parts of the machine.
2. Remove the suction protection (23).
3. Remove the lter (22) from the bottom of the machine
by releasing the overow (21).
4. Wash the lters under running water and t them cor-
rectly back in their housings.
ATTENTION
Frequently check and clean the spraying units, removing
them from their housings and eliminating any dirt and
fouling. The frequency with which this operation must be
carried out depends on the quantity of dirt or on the unsa-
tisfactory washing results. Never use corrosive products
like sodium hypochlorite (bleach) or hydrochloric acid, wire
wool or steel brushes to clean either the inside or outside
parts of the machine.
2.3. PREVENTION MAINTENANCE (Fig. 10)
The preventive maintenance operations must be carried
out with the machine OFF, the main circuit-breaker di-
sconnected, the water delivery cocks off and the washing
tub empty.
2.3.a Checking and cleaning the spray arms and
nozzles (Fig. 10)
Periodically check to make sure that the lower washing
arm and rinsing arm (24/25) and their relative nozzles are
not clogged (26/27).
Cleaning the lower/upper unit
1. Unscrew the ring nut (28) and lift the arm (24/25).
2. Wash the washing and rinsing arm.
If the nozzles (26/27) are clogged, unscrew them to
demount and clean, taking care to prevent the shape
of the nozzle from being deformed. After cleaning, t
the nozzles exactly back in their original positions.
3. Remount all parts by complying with the above instruc-
tions in reverse.
2.4 DESCALING
Where hard water is present lime scale deposits will
for in the machine and on dishes, which must, for re
sons of hygiene, be removed by descaling.
Advice on operation procedures and frequency for this
treatment are generally given by the detergent
supplier,who can provide suitable products.
In order to avoid damaging the machine, do not
exceed recommended doses, follow the detergent
producer’s directions scrupulously and, having
nished operations, rinse thoroughly.
2.5 TEMPORARY STOPPAGE
If the machine is to be left inactive for a period of
some weeks, it is advisable beforehand to load the
tank and run a few empty cycles with clean water then
drain, so as to avoid the formation of unpleasant
odours.
If necessary, repeat the process several times until the
water is still clean after washing.
If the stoppage is to be very long, it is advisable to
drain the water from the boiler and from the electric
pump.
2.6 DEMOLITION and DISPOSAL
When the machine is to be scrapped, drain the water
from the tank and from the boiler, as indicated in the
points above, and disconnect the machine from the
water and electricity supply networks, then dispose of
the components according to current regulations,
respecting national and local ecological and
environmental legislation, and taking care to separate
the parts as follows:
- metallic parts: body work, surfaces, panels, lters;
- electrical parts: motors, remote switches, micro-
switches, cabling;
- plastic parts: connectors, baskets;
- rubber parts: tubes, couplings
2.7 SCHEDULED MAINTENANCE
It is advisable to subject the machine to scheduled
maintenance every 6 months.
The producer declines all responsibility for any
printing errors contained in this booklet.
The instructions, drawings, tables and
everything else in this manual are of a con-
dential technical nature. For this reason, none
of the information may be either completely
or partially duplicated or disclosed to third
parties without prior written authorization
from HOONVED which is the sole proprietor
and which reserves the right to make any mo-
dications as may be considered necessary
without advance warning.
15


Need help? Post your question in this forum.

Forumrules
1

Forum

hoonved-ap48e

Reset search

  • fehlermeldung H2 bei einem AP48E Gläserspüler , was tun?
    Submitted on 31-7-2019 at 17:17

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hoonved AP48E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hoonved AP48E in the language / languages: English as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hoonved AP48E

Hoonved AP48E User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info