585432
10
Zoom out
Zoom in
Previous page
1/32
Next page
Changing batteries
10
3.4. Installing the window contact
Connect any sensor with floating contact to the HCW 82
(installation to connection 1 and connection 2, see
Fig. 7(2), Page 9).
For commissioning follow the instructions of the device to
which the window contact is assigned.
If several floating contacts are used, these have
to be connected in series.
4. Changing batteries
Change the batteries if the red LED of the room temperature
sensor flashes and the device is not in test mode.
Remove the housing cover of the HCW 82/HCF 82
(see Fig. 1).
Remove the batteries.
Dispose of the batteries according to the
local statutory requirements and not with
the used domestic refuse.
Always replace both batteries together.
Only use 1.5 V batteries of the type LR06, AA.
Insert the batteries with the right polarity into the batteriy
compartment (see Fig. 2).
Place the housing cover on at the top and latch it in
downwards (see Fig. 4).
5. Checking radio
transmission
The HCW 82/HCF 82 can send a test signal to the allocated
receiver (for example an underfloor heating controller) in
order to test the signal strength.
Keep the Bind button pressed for at least 30 s until the red
LED extinguishes.
The device is now in test mode and sends a test signal
every 5 seconds.
The LED flashes briefly at every test signal.
Check the radio transmission at the receiver. Refer to the
respective instructions for information about receiving and
evaluating the test signals.
The test mode is terminated automatically after
5 minutes. The test mode can also be terminated
by removing the batteries, manual disconnection
of the power supply or by pressing the Bind
button.
6. Help with problems
Problem Cause Remedy
Batteries
inserted
incorrectly
Insert the batteries
correctly.
Binding failed
Radio
connection
failure
Eliminate interference
sources (metal, wireless
devices).
Correct installation site.
Repeat the binding
procedure.
7. Technical data
Batteries 1.5 V, type LR06, AA
Power supply unit
3 V DC ± 10 %, min. 25 mA
Cable for power
supply unit/window
contact
2x0.8 mm; 2x0.5 mm²
max. length 100 m
Frequency 868.3 MHz (transmitter)
8. WEEE directive 2002/96/
EC - Waste Electrical and
Electronic Equipment
directive
At the end of the product life dispose of
the packaging and product in a
corresponding recycling centre.
Do not dispose of the unit with the usual
domestic refuse.
Do not burn the product.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HCF 82 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HCF 82 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info