Contents
1. Overview ............................................................... 7
1.1. Application............................................................. 7
1.2. Differences HCW 82/HCF 82 ................................ 7
1.3. Scope of delivery................................................... 7
2. Commissioning...................................................... 7
2.1. Binding .................................................................. 8
2.1.1. Assignment to underfloor heating controller .......... 8
2.1.2. Assignment to evotouch ........................................ 8
2.1.3. Failed binding........................................................ 8
2.2. Installation ............................................................. 8
3. Particular features of HCW 82............................... 9
3.1. Operation .............................................................. 9
3.2. Limiting the adjustment range ............................... 9
3.3. Operation with an external power source.............. 9
3.4. Installing the window contact............................... 10
4. Changing batteries .............................................. 10
5. Checking radio transmission ............................... 10
6. Help with problems.............................................. 10
7. Technical data ..................................................... 10
8. WEEE directive 2002/96/ EC - Waste Electrical
and Electronic Equipment directive ..................... 10
1. Overview
The HCW 82/HCF 82 room devices are used for intelligent
room temperature control. The room temperature sensor
HCF 82 measures the room temperature and sends the
measured values to other devices.
The HCW 82 measures the room temperature and
additionally allows the room setpoint temperature to be
adjusted.
1.1. Application
The room devices transfer the data with 868.3 MHz. The
data can be received by other devices such as the
underfloor heating controller HCE 80/HCC 80/HCE 80R/
HCC 80R or the evotouch.
Thus a large spectrum of applications can be covered.
1.2. Differences HCW 82/HCF 82
The HCW 82 has the following functions in addition to those
of the HCF 82:
Connection possibility for an external power supply unit
(see "Operation with an external power source", Page 9).
Connection possibility for a window contact
(see "Installing the window contact", Page 10).
Adjustment dial at which you can change the room
temperature setpoint directly.
The adjustment range amounts to ± 12 °C, starting from
the basic value of 20 °C (in position 0).
1.3. Scope of delivery
1 HCW 82/HCF 82
2 AA batteries
2. Commissioning
WARNING
Insufficient data transfer!
Interference of the radio receiver in the
device through metallic objects or
further radio devices.
Ensure there is sufficient distance to
metallic objects.
Mount the device with a distance of at
least 1 m to radio devices such as
radio headphones, cordless phones
according to the DECT standard, etc.
Select another installation site if the
radio interference cannot be rectified.
1
2
Fig. 1: Removing the housing cover
Remove the housing cover of the room temperature
sensor (see Fig. 1).
Fig. 2: Battery polarity and Bind button
Insert the supplied AA batteries with the correct battery
polarity (see Fig. 2).
The batteries have to be replaced when the red LED at the
HCW 82/HCF 82 flashes (see "Changing batteries",
Page 10).
The setpoint adjuster HCW 82 can also be
operated with an external power source instead
of with batteries. Further information can be
found in section "Operation with an external
power source", Page 9.
Place the room temperature sensor at the installation site,
but do not install it yet.
Allocate the corresponding temperature zone to the
HCW 82/HCF 82 (see "Binding", Page 8).
Red LED
Bind button
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HCF 82 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HCF 82 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info