The HC60NG is a radio frequency (RF) device and for the best perform-
ance should be installed in an open space. Leave at least 30cm distance
from any metal objects including wall boxes and the boiler.
2
NOTE:
The HC60NG contains no user serviceable parts. It should be opened and
installed by qualified installer only.
WARNING:
Electrostatic sensitive device! Do not touch the circuit board.
> 7mm
< 7mm
1.0-2.5mm²
6mm max.
NOTE:
Install in accordance with local wiring regulations
CAUTION:
Observe ambient temperature and current limits (see HC60NG wiring label)
Section 4:
HC60NG Relay Module
Caution!
!
When selecting the operating site of the HC60NG ensure that the dis-
tance to other wireless devices such as wireless headphones, cordless
phones etc. is at least 1-2m.
The HC60NG Relay Module is an integral part of the CM Zone Control System. It is
designed to control a Domestic Boiler, Valve, pump or Electric Heating appliances.
In the standard CM Zone Pack the HC60NG Relay Module is configured to control a Boiler
based upon demand signals received from the HR80UK Radiator Controllers either directly
or via a ‘Y Plan’ / ‘S Plan’ connection described below.
For control of other applications see Section 8: Changing the Configuration.
Please note: Maximum wire size 2.5mm
2
. SPDT relay suitable for
24...230V~, 10A resistive, 3A inductive
Honeywell ‘Y Plan’ Connections Honeywell ‘S Plan’ Connections
NOTE:
For existing ’Y Plan’ remove only Room Thermostat connections from
Junction Box Terminals and replace with Connections to HC60NG.
NOTE:
For existing ’S Plan’ remove only Room Thermostat connections from
Junction Box Terminals and replace with Connections to HC60NG.
HC60NG Relay Module
Typical Burner / Boiler connections
a. Burner (direct control)
HC60NG
b. Combi boiler
HC60NG
1 2 3 4 5 6 7 8 9 10
Typical ‘Y Plan’ Junction Box
HC60NG
1 2 3 4 5 6 7 8 9 10
Typical ‘S Plan’ Junction Box
HC60NG
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HC60NG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HC60NG in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info