9.2 Manual adaption
Manual adaption can be used to solve various problems:
if automatic adaption does not work.
if the entire valve lift is to be utilized.
if the radiator hardly gets warm at all.
if the radiator does not become cold.
if the
symbol is displayed (no adaption possible).
if the
symbol is displayed (valve lift too short or motor
cannot be moved).
Section 9: Trouble Shooting (cont.)
9.1 Trouble Shooting Guide (cont.)
Symptom (Fault Message)
CM67z display works but heat-
ing does not switch on:
The HC60NG LEDs are OFF
The HC60NG green LED is ON
HC60NG red LED is constantly
ON or flashing.
The HR80UK display is blank
or shows bAtt.
The ( ) symbol on the HR80UK
is not displayed.
Possible Cause
No power to HC60NG.
Bad electrical connection to the
boiler or faulty boiler.
RF communication lost due to bad
location of the CM67z room unit.
RF communication fault.
HR80UK batteries exhausted.
RF communication lost due to bad
location of the CM67z room unit.
RF communication fault.
Remedy
Check the power to the HC60NG is on.
Check the boiler and HC60NG power supply as well as electrical
connection between the boiler and HC60NG.
Hook the room unit back on the wall bracket or return the room unit
on the table stand to the position where communication was reliable.
Call the Honeywell Technical Help-Desk, details on the back page.
NOTE: The boiler can be controlled manually when RF communication
is lost. Press the HC60NG push button to switch the boiler on or off.
When the green LED is on - the boiler is on.
Replace the HR80UK batteries following the guidelines in the
HR80UK user instruction.
Hook the room unit back on the wall bracket or return the room
unit on the table stand to the position where communication was
reliable.
Call the Honeywell Technical Help-Desk, details on the back page.
During Normal Operation
9.4 Resetting the HR 80 to the factory settings
Separate operating unit from the coupling module (Fig.
1
).
Remove the batteries.
Insert the batteries again while keeping the binding
procedure button pressed.
Attach the operating unit to the
coupling module (Fig.
2
)
.
9.3 Def (default setting) and Full operating modes
In order to change between the two
operating modes, press the ‘binding
button’ until the respective operating
mode is shown on the display.
Def (default setting) operating mode
The HR 80 operates with the optimum valve lift that is required
for room temperature control.
Full operating mode
If the complete valve lift is to be used or if the valve does
not close completely, you have to set the HR 80 to the full
operating mode.
The battery lifetime is reduced in the full operating
mode.
Binding
Button
a
1
a
2
Turn the locking knob
a
and seperate the operating unit and
coupling module.
Attach the operating unit to the
coupling module and turn the
locking knob
a
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HC60NG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HC60NG in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info