624987
36
Zoom out
Zoom in
Previous page
1/40
Next page
Owner’s Manual
EX5500
00X31 -ZAO-6000
Thank you for purchasing a Honda generator.
This manual covers operation and maintenance of the EX5500 generator. All
information in this publication is based on the latest product information
available at the time of approval for printing.
Honda Motor Co., Ltd. reserves the right to make changes at any time without
notice and without incurring any obligation.
.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and
remain with the generator when sold.
Pay special attention to statements preceded by the following words:
m Indicates a strong possibility of severe personal injury or loss of
life if instructions are not followed.
CAUTION: Indicates a possibility of personal injury or equipment damage if
instructions are not followed.
NOTE: Gives helpful information.
If a problem should arise, or if you have any questions about the generator,
consult an authorized Honda dealer.
B The Honda generator is designed to give safe and dependable
service if operated according to instructions. Read and understand the
Owner’s Manual before operating the generator. Failure to do so could result
in personal injury or equipment damage.
CONTENTS
CONTENTS
1. GENERATOR SAFETY ....................... 1
2. COMPONENT IDENTIFICATION .................. 2
3. PRE-OPERATION CHECK ...................... 4
4. STARTING THE ENGINE ......................
8
5:GENERATOR USE ..........................
12
6. STOPPING THE ENGINE ....................... 14
7. MAlNTENAi)lCE ........................... 16
8. TRANSPORTING/STORAGE .................... 25
.
9. TROUBLESHOOTING
........................
27
10. SPECIFICATIONS .......................... 29
11. WIRING DIAGRAM
.........................
30
12. INSTALLATION OF OPTIONAL PARTS ................
31
I. GENERATOR SAFETY
To ensure safe operation -
l
Place the generator at least 1 m (3 ft) away from buildings or other
equipment when operating the generator.
l
Operate the generator on a level surface.
If the generator is tilted, fuel spillage may result.
l
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.
l
Know how to stop the generator quickly and understand operation of all
the controls. Never permit anyone to operate the generator without proper
instructions.
l
Keep children and pets away from the generator when it is in operation.
l
Keep away from rotating parts while the generator is running.
l
The generator is a potential source of electrical shocks when misused; do
not operate with wet hands.
Do not operate the generator in rain or snow and do not let it get wet.
2. COMPONENT IDENTIFICATION
AIR CLEANER
TOP COVER LOCK L
.GROUND
TERMlNAL--------
ENGINE OIL FILLER CAP
r
--
- -ENGINE OIL FILTER
FUEL GAUGE
MUFFLER
2
CONTROL BOX
VOLTAGE
ADJUSTMENT
KNOB
PILOT LAMP
VOLTMETER
Cl RCUIT
BREAKERS
AUTO-THROTTLE
SWITCH
RESET BUTTON
REMOTE
r
CONTROL SWITCH
ENGINE
1 FUEL VALVE
KNOB
AC RECEPTACLES
SWITCH
3
2. Check the fuel level.
Use any regular grade automotive gasoline (unleaded gasoline is preferred)
with a pump octane rating of 86 or higher.
Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust
or water in the fuel tank.
CAUTION: Gasoline substitutes are not recommended; they may be
harmful to the fuel system components.
Fuel tank capacity: 16.5 P (4.36 US gal 1
mm!!
.
Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine stopped.
Do not smoke or allow flames or sparks in the area where the generator
is refueled or where gasoline is stored.
Do not overfill the tank and make sure the filler cap is securely closed
after refueling.
Be careful not to spill fuel when refueling. Fuel vapor or spilled fuel may
ignite. If any fuel is spilled, make sure the area is dry before starting the
engine.
FUEL HANK CAP
5
3. Check the coolant level.
If there is no coolant in the reserve tank, check the cooling system for leaks
and repair if necessary. Add coolant to the radiator, then check the coolant
level in the reserve tank after the engine reaches operating temperature.
M Never remove the radiator cap when the engine is hot. The coolant
is under pressure and severe scalding could result.
When the engine is at operating temperature, the coolant level should be
between the
MIN
and
MAX
marks on the reserve tank. If the level is near
the MIN mark, add coolant to bring it up to the MAX mark.
Coolant Recommendation
Use high quality ethylene glycol antifreeze that is specifically formulated for
use in aluminum engines. Mix the antifreeze with low-mineral drinking water
or distilled water.
A 50/50 mixture of ethylene glycol antifreeze and water is recommended for
most temperatures and provides good corrosion protection. A higher
concentration of antifreeze decreases cooling efficiency and is recommended
only if additional protection against freezing is needed. A concentration of
less than 40% antifreeze will not provide proper corrosion protection.
CAUTION: The use of unsuitable antifreeze, hard water, or salt water may
cause corrosion damage that will shorten the life of the engine.
lLOWER LEVEL)
RESERVE TANK
6
4. Check the battery.
The electrolyte level must be maintained between the UPPER and LOWER
level marks. If the electrolyte level is near the LOWER mark, add distilled
water.
l
The batterv contains sulfuric acid. Avoid contact with skin, eyes or
clothing. Antidote: EXTERNAL - Flush with water. INTERNAL -
Drink large quantities of water or milk. Follow with milk of magnesia,
beaten egg or vegetable oil. Call a physician immediately. Eyes: Flush
with water and get prompt medical attention.
l
Batteries produce explosive gases. Keep sparks, flames and cigarettes
away. Always shield the eyes
when working near batteries.
CAUTION:
l
Use only distilled water in the battery. Tap water will shorten the service
life of the battery.
l
Do not fill the battery beyond the UPPER level. If overfilled, electrolyte
may overflow and corrode generator components. Immediately wash off
any spilled electrolyte.
Check the battery terminals to be sure
corrosion. Remove any corrosion and
with grease.
the cables are tightened and free of
coat the terminals and cable ends
UPPER LEV
LOWER LEVEL
7
4. STARTING THE IENGINE
1. Turn the fuel valve ON.
4
-
, -
8
2. Make sure that the circuit breakers are OFF.
The generator may be hard to start if a load is connected.
(
9
CIRCUIT-BREAKERS
II
0
0
c
c
-
3. Make sure the auto-throttle switch is off, or more time will be required for
warm up.
AUTO-THROTTLE SWITCH
9
4.Turn the engine switch to START and hold it there until the engine starts.
Do not use the electric starter for more than 5 seconds at a time. If the
engine fails to start, release the switch and wait 10 seconds before operating
the starter again.
NOTE:
l
When the speed of the starter motor drops after a period of time,
indication
that the battery should
be recharged
it is an
NOTE: It is normal for the oil lamp to remain lit during starting.‘ If the oil
level is OK, the oil lamp will go off when the engine is running. If the oil level
is low, the oil lamp will stay on; the engine may start but will not continue to
run.
10
5. After the engine starts, let the engine-switch return to ON.
ENGINE SWITCH
6. Warm up the engine for 2-3 minutes. Turn the auto-throttle switch to
AUTO after the engine has warmed up.
Operation
1. Start the engine and make sure that the pilot lamp comes on.
2. Switch on the circuit breakers.
3. Plug in the appliance.
NOTE: Connect 120V appliances to the 120V receptacles. You can use both
12OV/24OV appliances with the 12OV/24OV receptacle.
CAUTION: Be sure that appliances do not exceed the rated load for more
than 30 minutes, and never exceed the maximum load. Substantial. over-
loading will switch off the circuit breaker. Lesser overloading will not switch
off the circuit breaker and will shorten the service life of the generator.
NOTE: This generator is equipped with an AVR (Automatic Voltage
Regulator).
Though voltage adjustment is not required, fine adjustments may be made by
turning the voltage adjustment knob. Use the generator at the specified
voltage.
AIR dlRCUlT
BREAKERS
13
6. STOPPING THE ENGINE
To stop the engine in an emergency, move the engine switch to OFF.
In normal use:
1. Turn the circuit breakers OFF.
CIRCUIT BREAKERS
I
I
I
2. Turn the engine switch OFF.
ENGINE SWITCH
14
3. Turn the fuel valve OFF.
FUELVALVE KNOB /
15
7. MAINTENANCE
The purpose of the maintenance schedule and adjustment is to keep the
generator in the best operating condition.
Inspect or service as scheduled in the table on the next page.
M Shut off the engine before performing any maintenance. If the
engine must be run, make sure the area is well ventilated. The exhaust
contains poisonous carbon monoxide gas.
CAUTION: Use only genuine HONDA parts or their equivalent. The use of
replacement parts which are not of equivalent quality may damage the
generator.
.
16
Maintenance Schedule
orm at every indi-
ating hour interval,
whichever occurs
NOTE (1 J : Service more frequently when used in dusty areas,
(2) : These items should be serviced by an authorized Honda dealer, unless the
owner has the proper tools and is mechanically proficient. See the Honda
Shop Manual.
Toll kit
The tools supplied are necessary for performing some periodic maintenance,
simple adjustments and repairs.
Always keep the kit with the generator.
Engine oil and oil filter change
Drain the oil while the engine is still warm to assure rapid and complete
draining.
1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug
securely, and reinstall the filler cap.
2. Remove the oil filter with a filter wrench and let the remaining oil drain
out.
3. Apply a thin coat of engine oil to the filter rubber seal and screw it in by
hand until you feel it seat against
the
engine, then turn it 314 of a turn
more.
4. Fill the crankcase with the recommended oil (See page 4) and check the
level. Recheck the level after running the engine for a few minutes.
Total oil capacity: 1.4 P
(1.48
US qt)
Air cleaner service
A dirty air cleaner will restrict air flow to the carburetor. To prevent
carburetor malfunction, service the air cleaner regularly (page 23). Service
more frequently when operating the generator in extremely dusty areas.
N Never use gasoline or low flash point solvents for cleaning the air
cleaner elements. A fire or explosion could result.
CAUTION: Never run the generator without the air cleaner. Rapid engine
wear may result.
1. Pull the lock levers out and open the top cover.
2. Unscrew the wing nut and remove the air cleaner cover.
3. Remove the urethane and paper elements.
WIN NUT
9
COVER
AIR CLEANid
ELEMENTS (URETHANE AND PAPER)
19
4. Carefully check both elements for holes or tears and replace as required.
Damaged elements will pass dirt into the system. Always clean the filter
housing and air passages before installing clean elements.
5. Foam element: Clean in warm soapy water: rinse and allow to dry
thoroughly. Or clean in high flash-point solvent and allow to dry. Dip the
element in clean engine oil and squeeze out all the excess. The engine will
smoke during initial start-up if too much oil is left in the foam.
6. Paper element: Tap the element lightly several times on a hard surface to
remove excess dirt, or blow compressed air through the filter from the
inside out. Never try to brush the dirt off: brushing will force dirt into the
fibers. Clean in warm, soapy water and rinse. Dry using compressed air
blown from the inside out, or shake the element and allow it to air dry
thoroughly. (Or clean in high flash-point solvent, remove immediately, and
allow to dry.) Oil the outside of the paper with a light aerosol oil such as
WD-46. The engine will smoke during initial start-up if too much oil is used.
7. Reinstall the elements and air cleaner cover with the arrow on the cover
aligned with the arrow on the frame. Tighten the wing nut securely.
8. Reinstall the top cover.
URETHA‘NE ELEMENT
20
Fuel filter service
The filter prevents dirt or water which may be in the fuel tank from entering
the carburetor. If the engine has not been run for a long time, the filter should
be cleaned.
1. Turn the two lock pins and open the carburetor cover.
2. Turn the fuel valve OFF. Remove the filter cup.
3. Clean the cup thoroughly.
4. Reassemble. Do not damage the O-ring.
5. Close the carburetor cover and lock with the lock pins.
B After installing the filter cup, check for fuel leaks and make sure
the area is dry before starting the engine.
FILTER CUP
21
Spark plug service
Recommended spark plug: BPRGHS-10 (NGK)
To ensure proper engine operation, the spark plug must be properly gapped
and free of deposits.
1. Pull the lock levers out and open the top cover.
2. Remove the spark plug cap.
3. Use the wrench supplied in the tool kit to remove the spark plug.
4. Visually inspect the spark plug. Discard it if the insulator is cracked or
chipped.
5. Measure the plug gap with a feeler gauge.
The gap should be 0.9-1.0 mm (0.035-0.039 in). Correct as necessary by
bending the side electrode.
6. Attach the plug washer.
Thread the plug in by hand to, prevent
cross-threading.
7. Tighten a new spark plug l/2 turn with the wrench to compress the washer.
If you are reusing a plug, it should only take l/8-1/4 turn after the plug
seats.
8. Reinstall the top cover.
CAUTION :
l
The spark plug must be securely tightened. An improperly tightened plug
can become very hot and possibly damage the generator.
l
Never use a spark plug with an improper heat range.
PLUG GAP
0.9-1.0
mm
(0.035-0.039
in1
PLUG WRENCH
Fuse replacement
If the fuse is blown, the engine will not start until it is replaced.
1. Pull the lock levers out and open the top cover.
2. Turn the engine switch OFF.
3. Remove the fuse holder and replace the fuse. Use only a 10A fuse.
4. Close the top cover.
CAUTION:
If frequent fuse failure occurs, determine the cause and correct the problem
before attempting to bperate the generator further.
Never use a fuse with a rating other than 10A. Serious damage to the
electrical system or a fire may result.
FUSE HOLDER
23
Spark arrester maintenance
m If the generator has been running, the muffler will be very hot.
Allow it to cool before proceeding.
CAUTION: The spark arrester must be serviced every 100 hours to maintain
its efficiency.
1. Loosen two 5 mm pan screws on the arrester cap.
2. Remove the arrester cap, then pull out spark arrester taking care not to
damage the wire mesh.
3. Check the muffler exhaust port for carbon deposits; clean if necessary.
4. Install the spark arrester and arrester cap on the muffler.
5. Tighten two 5 mm pan screws to the arrester cap.
_
ARRESTER
ARRESTER CAP
24
8. TRANSPORTING/STORAGE
m When transporting the generator, turn the engine switch OFF and
keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may
ignite.
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Drain the fuel -
a. With the fuel valve OFF, remove and empty the filter cup.
b. Turn the fuel valve ON and drain the gasoline in the fuel tank into a
suitable container.
c. Replace the filter cup and tighten securely.
FILTER CUP
25
d. Drain the carburetor by loosening the drain screw. Drain the gasoline
into a suitable container.
--
P
DRAIN SCREW
3. Once a month, recharge the battery.
26
9. TROUBLESHOOTING
A. When the engine will not start:
1. Is there enough fuel?
2. Is the fuel valve on?
3. Is gasoline reaching the carburetor?
To check, loosen the drain screw with the fuel valve on.
bw If any fuel is spilled, make sure the area is dry before testing
the
spark
plug or starting the engine. Fuel vapor
or
spilled fuel may
ignite.
DRAIN SCREW
I
4. Is the reset button pushed in?
5. Are the circuit breakers off?
6. Is the engine
switch on?
7.
Is the fuse good?
8. Is there a spark at the spark plug (Page 28)?
27
a. Remove the spark plug cap. Clean any dirt from around the spark
plug base, then remove the spark plug.
b. Install the spark plug in the plug cap.
c. Turn the engine switch on.
d. Grounding the side electrode to any engine ground, crank the
engine to see if sparks jump across the gap.
e. If there are no sparks, replace the plug.
If OK, try to start the engine according to the instructions.
9. If the engine still does not start, take the generator to the dealer.
B. When the engine starts but stops immediately:
a. Is there enough oil in the crankcase?
If not, the oil lamp will go on.
b. Is there enough coolant in the radiator (is the engine overheated)?
If not, the coolant lamp will go on.
C. No electricity at the output receptacles:
Are the circuit breakers on?
28
10. SPEClFlCATlONS
Dimension
Length x Width x Height
Dry weight
965x590x730mm
(38.0 x 23.2 x 28.7 in)
175 kg (385.9 lb)
Engine
Model
Honda GX360
Engine Type 4Stroke, O.H.C. 2 cylinder
Displacement
359
cm3 (21 .Q cu in)
[Bore x Stroke] (58 x 68 mm (2.3 x 2.7 in)1
Compression Ratio 8.5 :1
Engine Speed
3,600 rpm
Ignition System
C.D.I.
Oil Capacity
1.4 P (1.48 US qt)
Cooling System Capacity
2.0 P (2.11 us qt)
Fuel Tank Capacity
16.5 P (4.36 US gal)
Spark plug BPRGHS-10 (NGK)
Generator
Rated voltage
12OJ240 V
1
Rated frequency
60 Hz
AC output Rated ampere
41.7120.8A
Rated output
5.0 KVA
Maximum output
5.5 KVA
29
c
=
-
12. INSTALLATION OF OPTIONAL PARTS
Remote control kit
The generator may be adapted for remote control operation by use of an
optional kit.
1. Unscrew the two 6 x 10 mm flange bolts and 6 x 8 mm screws attaching
the control panel. Remove the control panel.
6 x 10 mm FLANGE BOLTS
2. Position the relay box on the back of the control panel with the studs
inserted through the holes in the relay box flange. Install a 4 mm nut and
lock washer on each stud and tighten securely.
3. Remove the 6-P coupler with a jumper wire from the wire harness female
coupler. Connect the relay box 6-P male coupler to the wire harness female
coupler.
4. Insert the relay box 6-P female coupler in the hole in the sub panel below
the control panel and install with the two self-tapping screws and coupler
holder.
4 x 10 mm SELF-
TAPPING SCREWS
CONTROL
COUPLER HOLDER
HOLE IN SUB PANEL
31
4 mm’NUT
5. Reinstall the control panel with the 6 x 10 mm flange bolts and 6 x 8 mm
screws.
6. Connect the remote control 6-P male coupler
to
the 6-P coupler on the sub
panel.
6-P FEMALE COUPLER
RE
CO
CA
7. Connect the remote control 6-P male coupler to the switch box.
32
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honda EX5500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honda EX5500 in the language / languages: English as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info