616688
7
Zoom out
Zoom in
Previous page
1/220
Next page
7
English
Table 1
Indications of the pilot lamp
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o for 0.5 seconds)
While charging Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o for 0.5 seconds)
Overheat
standby
Blinks
Lights for 1 second. Does not light for 0.5
seconds. (o for 0.5 seconds)
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Charging
impossible
Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o for 0.1 seconds)
Malfunction in the
battery or the charger
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot lamp
will blink in red. (At 1-second intervals) (See Table 1)
Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Regarding the temperatures and charging time of the
battery.
The temperatures and charging time will become as
shown in Table 2.
Table 2
Charger
Battery
UC18YFSL
Charging voltage V 14.4 18
Weight kg 0.5
Temperatures at which the battery
can be recharged
0oC 50oC
Charging time for battery capacity,
approx. (At 20oC)
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
min.
min.
min.
min.
min.
min.
22
30
35
45
60
75
Number of battery cells 4 10
NOTE
The recharging time may vary according to temperature
and power source voltage.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
CAUTION
If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of the charger lights for 1 second, does not
light for 0.5 seconds (o for 0.5 seconds). In such a case,
rst let the battery cool, then start charging.
When the pilot lamp ickers (at 0.2-second intervals),
check for and take out any foreign objects in the charger’s
battery connector. If there are no foreign objects, it is
probable that the battery or charger is malfunctioning.
Take it to your authorized Service Center.
Since the built-in micro computer takes about 3 seconds to
con rm that the battery being charged with charger is taken
out, wait for a minimum of 3 seconds before reinserting it
to continue charging. If the battery is reinserted within 3
seconds, the battery may not be properly charged.
If the pilot lamp does not blink in red (every second)
even though the charger cord is connected to the power,
it indicates that the protection circuit of the charger may
be activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the Hitachi Authorized Service
Center.
MOUNTING AND OPERATION
Action Figure Page
Fine tuning of parallelism 9 206
Fine tuning of perpendicularity 10 206
Fine tuning of guide piece position 11 206
Adjusting the cutting depth 12 207
Cutting line 13 207
Switch operation 14 207
About the mode select function (*1) 15 207
Remaining battery indicator 16 207
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hitachi C18DBAL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hitachi C18DBAL in the language / languages: All languages as an attachment in your email.

The manual is 28,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info