816375
9
Zoom out
Zoom in
Previous page
1/204
Next page
9
English
NOTE
To prevent the battery power consumption caused by
forgetting to turn o the LED light, the light goes o
automatically in about 3 seconds.
STANDARD ACCESSORIES
In addition to the main unit (1), the package contains the
accessories listed on page 192.
Standard accessories are subject to change without notice.
SPECIFIED CONDITIONS OF USE
The tools are suitable for screwing into gypsum plasterboard
on timber and metal substructures
and gypsum bre board up to 12.5 mm on metal
substructures.
W18DB is also suitable for gypsum bre board up to
12.5 mm on timber substructures and on lay plates,
and for chipboard (OSB) on timber substructures.
The machines are not suitable for inserting and removing
screws in metal materials.
The user bears sole responsibility for any damage caused
by inappropriate use.
Generally accepted accident prevention regulations and the
enclosed safety information must be observed.
SPECIFICATIONS
1. Power tool
Model W18DA W18DB
Voltage 18 V
No load speed 0–5000 min–1 0–3000 min–1
Screw size 4 mm
Bit shank size 6.35 mm Hex.
Battery available
for this tool* Multi volt battery, BSL18 series
Weight**
BSL1820M : 1.4 kg
BSL1840M : 1.6 kg
BSL36B18 : 2.0 kg
BSL1820M : 1.5 kg
BSL1840M : 1.7 kg
BSL36B18 : 2.1 kg
* Existing batteries (BSL3660/3620/3626) cannot be used
with this tool.
** According to EPTA-Procedure 01/2014
NOTE
Due to HiKOKI’s continuing program of research and
development, the speci cations herein are subject to
change without prior notice.
2. Battery
Model BSL1820M BSL1840M
Voltage 18 V
Battery capacity 2.0 A 4.0 A
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect the charger’s power cord to the receptacle.
When connecting the plug of the charger to a receptacle,
the pilot lamp will blink in red (At 1- second intervals).
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 4.
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot lamp
will blink in red. (At 1-second intervals) (See Table 1)
Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Table 1
Indications of the pilot lamp (RED)
Before
charging
Lights on for
0.5 seconds and o
for 0.5 seconds
Blinks
Plugged into power
source
While
charging
Lights continuously
Lights
Charging
complete
Lights on for
0.5 seconds and o
for 0.5 seconds
Blinks
Overheat
standby
Lights on for
1 second and o for
0.5 seconds
Blinks
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Charging
impossible
Lights on for
0.1 seconds and o
for 0.1 seconds
Flickers
Malfunction in
the battery or the
charger
Regarding the temperatures and charging time of the
battery.
The temperatures and charging time will become as
shown in Table 2.
Table 2
Charger
Battery UC18YFSL
Charging voltage V 14.4–18
Weight kg 0.5
Temperatures at which the battery
can be recharged 0°C–50°C
Charging time for battery capacity,
approx. (At 20°C)
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
6.0 Ah
8.0 Ah
min
min
min
min
min
min
min
min
22
30
35
45
60
75
90
120
Number of battery cells 4–10
NOTE
The recharging time may vary according to temperature
and power source voltage.
00BookW18DA.indb900BookW18DA.indb9 2022/05/2318:06:012022/05/2318:06:01
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hikoki W18DB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hikoki W18DB in the language / languages: All languages as an attachment in your email.

The manual is 10.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info