647373
17
Zoom out
Zoom in
Previous page
1/43
Next page
BOXER / MARLIN / FALCON / POLAR SERIES USER MANUAL
Version 06.03 DIG.EN 17
6. Seal function When the vacuum function or gas flush function (if installed) ends, the seal function starts to
seal the vacuum bag(s).
The light in front of [SEAL] goes on.
Large Display: decrementing time per second starting at the time set (max. 6.0 sec.).
The reading on the vacuum meter stays the same.
7. Soft-air ventilation function After ending the seal function the soft air function starts to slowly ventilate the
(if installed) vacuum chamber.
The light in front of [SOFT AIR] goes on.
Large Display: decrementing time per second starting at the time set (max. 99 sec.).
Vacuum meter starts slowly decreasing to the right.
8. Ventilation function After ending the seal function or the soft air function (if installed) the ventilation function starts
ventilating the chamber to 1 atmosphere/ATO and the lid opens.
There are no longer any lights on in front of the functions.
Large Display: lines going up and down until the lid is opened.
The vacuum meter runs back to the right to zero and the lid opens automatically.
9. The product is packed and ready to remove.
PROGRAM MODE
The program mode is used to change the function values within the programs. See page 18-20 for instructions on
programming.
OTHER MODES
The control panel also includes a service mode. The conditioning program (see page 22) for the pump and the operation
hours counter are the functions most used in this mode.
Operation Hours Counter
One of the service functions is the operation hours counter in order to be able to automatically indicate regular service
requirements. This functions sets the number of hours that the pump runs (per 10 hours). Note that for BOXER series
and MARLIN 42-42 XL, the pump does not run continuously. Once the number of hours set has been exceeded, the
message [OIL] appears on the display (see page 11). The machine can still be used as usual but the message will keep
reappearing on the display.
The factory setting for the program operation hours counter is OFF (turned off). The following steps can be followed to
activate the operation hours counter or to reset it:
Press the FUNCTION SELECT Key for at least 3 seconds. After 3 seconds the number of operating hours
(per 10 hours) will be displayed for about 2 seconds. After 2 seconds the originally set number of hours will
be displayed (per 10 hours). When the operation hours counter is turned off, the number of operating
hours will not be displayed, instead the message [OFF] will immediately appear after pressing the key for 3
seconds.
The original setting can be modified using the + and – keys (between 0 and 990 hours). If set to 0 then the next time
[OFF] will automatically be displayed. The new settings are stored by using the REPROG Key. The actual operation
hours are then also reset to zero.
After pressing the REPROG key, the control panel automatically switches over to operation mode.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Henkelman MARLIN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Henkelman MARLIN in the language / languages: English as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Henkelman MARLIN

Henkelman MARLIN User Manual - German - 44 pages

Henkelman MARLIN User Manual - Dutch - 43 pages

Henkelman MARLIN User Manual - French - 46 pages

Henkelman MARLIN User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info