PROGRAMMING
The function values in a selected program number can be changed using either manual or automatic programming. For
units, range and limits of the function values refer to the previous chapter, MACHINE CONTROL PANEL.
10 programs can be selected and set, number 0 to 9. Note: program 0 cannot be programmed. The values in this
program are set for service and reference use.
MANUAL PROGRAMMING
A. Select the correct program with PROG 0-9 key for setting function values.
Program number is displayed on the small display.
B. Press REPROG key
to switch into program mode.
The program number now starts to blink on the small display.
C. Select the required function for programming with the FUNCTION SELECT Key
.
The indicator lights will turn on for the active functions when selected.
Remark on Seal function for option 1-2 cut-offseal
At option 1-2 cut-offseal, the indicator SEAL lights up twice when selected. The
first time is for setting the seal time and the second time for setting the cutting
time.
Remark on option Digital Sensor Control
At option sensor control, the indicator VACUUM lights up twice when selected.
The first time for the vacuum function (vacuum percentage)
The second time for the vacuum plus function (time duration), see pages 14,16
D.
Digital Time Control
Set the amount of time required for the selected function by using
the + and – keys
.
Digital Sensor Control
Set the percentage of vacuum required or the amount of time required for the
selected function by using the + and – keys
.
Remarks
Set values are displayed on the large display.
The functions vacuum plus (sensor control), gas flush and soft air can be turned
off in the programme if required. For turning off a function press the – key
until
OFF appears on the large display.
E. Repeat steps C and D for setting other function values.
F. Press the REPROG key after setting all relevant functions to store the changes
in the program. The control then automatically switches back to operation mode
and the machine is ready for use. The newly set values are now the new default
values.
Starting situation: machine is in normal operation mode and the lid is open
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Henkelman FALCON at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Henkelman FALCON in the language / languages: English as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Henkelman FALCON

Henkelman FALCON User Manual - German - 44 pages

Henkelman FALCON User Manual - Dutch - 43 pages

Henkelman FALCON User Manual - French - 46 pages

Henkelman FALCON User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info