4. Gas flush function Once the vacuum function has completed then the gas flush function starts to flush gas into
(if installed) the vacuum chamber.
The light in front of [GAS] goes on.
Large Display: decrementing time per second starting at the time set (max. 99 sec.).
Vacuum meter starts decreasing to the right.
5. Seal function When the vacuum function or gas flush function (if installed) ends, the seal function starts to
seal the vacuum bag(s).
The light in front of [SEAL] goes on.
Large Display: decrementing time per 0.1 second starting at the time set (max. 6.0 sec.).
The reading on the vacuum meter stays the same.
6. Soft-air ventilation function After ending the seal function the soft air function starts to slowly ventilate the vacuum
(if installed) chamber.
The light in front of [SOFT AIR] goes on.
Large Display: decrementing time per second starting at the time set (max. 99 sec.).
Vacuum meter starts slowly decreasing to the right.
7. Ventilation function After ending the seal function or the soft air function (if installed) the ventilation function starts
ventilating the chamber to 1 atmosphere/ATO and the lid opens.
There are no longer any lights on in front of the functions.
Large Display: lines going up and down until the lid is opened.
The vacuum meter runs back to the right to zero and the lid opens automatically.
8. The product is packed and ready to remove.
Description of the program cycle for digital sensor control
1. Select the program number with the PROG key and the small display.
If the selected program is programmed with the active gas flush function then a dot appears in the lower right hand corner of the
small display.
If the selected program is programmed with the active VACUUM PLUS function then a dot appears in the lower right hand corner
of the large display.
2. Close the lid.
3. Vacuum function The machine starts to vacuum the chamber.
The light in front of [VACUUM] goes on.
Large Display: incrementing percentage vacuum until the percentage set (max.. 99%) and a
dot in the lower right hand corner if the VACUUM PLUS function is activated.
Vacuum meter starts increasing to the left.
4. VACUUM PLUS function The machine continues vacuuming the chamber after 99% value is reached.
(if installed) The light in front of [VACUUM] goes on.
Large Display: decrementing time per second starting at the time set (max. 99 sec.). and a
dot in the lower right hand corner.
The vacuum meter will very slowly increment to the left (hardly noticeable).
Remark: can only be installed with a vacuum function whereby the value is set to the
maximum of 99%.
5. Gas flush Function Once the vacuum function has completed then the gas flush function starts to flush gas into
(if installed) the vacuum chamber.
The light in front of [GAS] goes on.
Large Display: decrementing percentage vacuum until the set percentage (min. 30%).
Vacuum meter starts decreasing to the right.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Henkelman FALCON at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Henkelman FALCON in the language / languages: English as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Henkelman FALCON

Henkelman FALCON User Manual - German - 44 pages

Henkelman FALCON User Manual - Dutch - 43 pages

Henkelman FALCON User Manual - French - 46 pages

Henkelman FALCON User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info