USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
25 Pump
4.5 Setting the Timer mode
The control panel allows you to program multiple sequences
(see section 2.3) or Timers t0 to t5, which do not need to follow a
chronological order.
Unused Timer settings will be deactivated.
Timer 't0' can be set to 00:00, 06:00 (by default), 12:00 or 18:00. It
cannot be deactivated.
You cannot adjust the speed of t0, it is set at 2400 rpm
speed
time
t0
t1
t3
(t2)
t4
t5
Identify the speed profile you would like to program.
The image opposite is shown as an example.
Check whether the internal clock has been set correctly.
Press and hold DISP/FUNC for 3 seconds
All 3 LEDs will blink and the screen will display
"ConF" >3s
ConF
Press DISP/FUNC twice and the screen will
display "t0" x 2
t 0
Press DISP/FUNC: the screen will display "06-00" -
this is the default value of t0 06-00
Press the up / down buttons to set the value you
would like for t0 (00-00, 06-00, 12-00 or 18-00) 18-00
Press DISP/FUNC: the screen will display "t1oFF" t1off
To activate this Timer setting (as an example),
press the 'up' button. The screen will display "t1
on"
t1 on
Press DISP/FUNC: the screen will display "00-00" 00-00
Press the up / down buttons to set the desired
timetable (hh-mm) 20-00 20-15
Press DISP/FUNC: the screen will display "0" 0
Press the up / down buttons to display the desired
speed (600 to 3000 rpm or 0) 2740
To go to the next Timer setting, press DISP/FUNC:
the screen will display "t2off". In this example the
Timer setting stays deactivated
t2off
Press DISP/FUNC to go to the next Timer setting
and repeat the steps (activation, timetable, Timer
setting and speed) etc ...
t3off
Press RUN/STOP to exit and save
The display will show the current speed or StoP StoP
/
1640
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward TriStar VSTD Pump at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward TriStar VSTD Pump in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 27.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info