801919
24
Zoom out
Zoom in
Previous page
1/192
Next page
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
23 Pump
4. SETTINGS
Note: To adjust the settings the pump must be powered on and in Manual mode (section 2.4), switched off or running
(post priming phase).
If no button is pressed for 2 minutes, the display will go back to normal (showing the speed or StoP) and the
settings will not be saved.
4.1 Setting the clock
Press and hold DISP/FUNC for 3 seconds
All three LEDs will blink
The screen will display "ConF" and then "hr" >3s
ConF
h r
Press DISP/FUNC to show the time on the internal
clock (hh-min) 07-38
Press the up / down buttons to adjust the hours /
minutes 15-38 15-10
Press RUN/STOP to exit and save
The display will show the current speed or StoP StoP
/
1640
Note: Adjusting the time on the internal clock is important in Timer mode.
It will remain saved if the pump is switched off.
4.2 Setting the priming phase
Press and hold DISP/FUNC for 3 seconds
All 3 LEDs will blink and the screen will display
"ConF" >3s
ConF
Press DISP/FUNC repeatedly until 'Pr 240' is
displayed on screen - the default priming time
(seconds) x n Pr240
Press the up / down buttons to set the desired
value (0 to 300 seconds) Pr 80
Press DISP/FUNC: the screen will display "o3000"
as default priming speed (rpm) o3000
Press the up / down buttons to display the desired
value (max. 3000 rpm) o2660
Press RUN/STOP to exit and save
The display will show the current speed or StoP StoP
/
1640
Note: If the priming time is set to zero the screen
will display "ProFF": priming has been
deactivated
ProFFPr 0
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward TriStar VSTD Pump at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward TriStar VSTD Pump in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 27.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info