Hayward only guarantees the quality, performance and safety of its products when assembled with genuine Hayward manufactured parts.
Use of non genuine Hayward manufactured parts will void all warranty.
Page 5 of 14 TigerShark / TigerShark QC / TigerShark 2 Rev. C
Use:
Take some time to become acquainted with your TigerShark by looking at the drawings (Figures 1 and 2).
Throughout the handbook we refer to these drawings when we are talking about the various components
of TigerShark.
1. Choose a 230 V
socket (outlet) that is close and protected from short-circuits. Fit a 30 mA differential protection device
to protect people from electric shock caused by a possible break in the electrical insulation.
2. Install the power supply box (1) so that your TigerShark can reach all of the walls/surfaces
of the pool. The power supply box should be at least 3.5 metres from the edge of the pool (Figure 1a).
The standard length of the TigerShark cable is 16.76 metres (TigerShark 2 : 30 metres).
3. Plug the oating cable into the power supply box.
Caution: use the original power supply box only.
4. TigerShark has an adaptable handle (3). The handle should be locked in the diagonal position in order
to guarantee optimum cleaning results. Reverse the position of the handle after use every time it is used (Figure 1b) to
enable the cord to be wound up without twisting.
5. Place TigerShark in the pool. It will sink gently to the bottom of the pool as it gradually empties itself
of the air that it contains.
6. Plug the power supply box into the socket and switch on the appliance. TigerShark will programme
a self-diagnostic test for a few minutes before it starts cleaning the pool.
Caution:
DO NOT SWITCH TigerShark ON OUTSIDE THE WATER. You might damage the pump and render the warranty NULL
AND VOID.
7. TigerShark switches off automatically after a 4-hour cycle (TigerShark 2 : 7 hours).
If your pool is clean in under 4 hours, you can switch off the cleaner by switching off the power supply box.
If a second clean is necessary, wait for 30 seconds before switching back on again.
8. Once the pool is clean, switch off the power supply box before you take TigerShark out of the water.
9. Take TigerShark out of the water from the shallow end of the pool by pulling the cable until the cleaner comes up to the
surface. Then, lift it out gently by using the handle, NOT the cable.
CAUTION: while pulling the cable, wind it in around both of your hands and above all not around your arm. To make
TigerShark last, remove the water from it after use, every time it is used.
DO NOT GO INTO THE POOL WHILE TigerShark IS OPERATING.
Check the height of the waterline on TigerShark:
- Ensure that the lter is clean.
- Put the cleaner in the water and observe the height of the waterline on the cleaner. For this purpose, let it perform several
cleaning cycles in order to determine an average height.
- Once the waterline is settled, if the cleaner regularly makes excessive rattling noises, takes air in through the bottom cover,
climbs up the edge of the wall instead of going back the other way, or if it tends to stagnate in the same zone of the pool, it
is probable that TigerShark is climbing too high: install the reducer kit.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward TigerShark QC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward TigerShark QC in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 6.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info