801903
22
Zoom out
Zoom in
Previous page
1/192
Next page
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
21 Pump
Operation with the digital inputs
The digital inputs can be operated in Manual or Timer
mode.
They have the highest priority level: they act as
MASTER over all the functions currently in use.
Only the Run/Stop and DISP/FUNC buttons remain
active.
When a digital input is used, the LED associated with
the speed in question blinks rapidly
(DI1 = V1, DI2 = V2 or DI3 = V3).
To obtain an action through the digital inputs, the DI4
input must be closed. DI4 Run/Stop Closed
If several digital inputs are switched simultaneously,
only one will be carried out in the order of priority
specified in the table opposite.
DI1 = V1 DI2 = V2 DI3 = V3
DI1 = V1 V1 V2 V3
DI2 = V2 V2 V2 V3
DI3 = V3 V3 V2 V3
N.B. Once the action associated with the digital input is complete (open contact),
the filtration pump resumes the action for the current operational mode.
If the DI4 digital inlet is open, the filtration pump will
not start and dSTOP will be displayed on the pump's
screen.
Close the DI4 inlet.
If necessary press RUN/STOP to start the filtration
pump.
DI1
DI2
DI3
DI4
C
dStoP
A
or
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward SuperPump VSTD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward SuperPump VSTD in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 27.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info