USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
17 Pump
GENERAL POINTS
Congratulations, you have just acquired a Hayward® variable speed pump.
Hayward® variable speed pumps® have a state-of-the-art permanent-magnet motor with AC electronic switching. This
motor is controlled by a microprocessor combined with a frequency variator providing the following characteristics:
Rotation speed is displayed on the control display
3 factory preset rotation speeds (buttons V1, V2, V3), as well as custom speeds set by the user
Regular priming each time you switch on, with adjustable speed and duration
Skimmer function, which skims the water's surface
Programmable Timer function
Current power usage displayed
Partial and total power consumption displayed
Running time of the pump displayed
Low noise level
Construction standard TEFC IP55
Install the pump at a suitable distance from the pool to reduce the distance between the suction point and the pump as
much as possible to avoid pointless excessive pressure drops on the hydraulic circuit.
However, it is essential to comply with the safety distance required by the current installation standard (3.5 m minimum).
Install and use the product at an altitude less than 2000 m
ZONE 2 ZONE 2
ZONE 0
1,50 m
2,50 m
2,50 m
1,50 m 2,00 m 2,00 m 1,50 m
ZONE 1
1,50 m
OK OK
3.5 m
ZONE 0
Install the pump in a dry, well-ventilated place. The motor requires the air to circulate freely around it to allow natural
ventilation. Clear a space of at least 0.5m around the pump. Check regularly that no objects, leaves or other debris are
blocking the motor cooling system.
The pump must be installed to ensure that the external disconnection switch incorporated into the fixed unit is visible and
easily accessible. The switch must be located near to the pump.
The pump must be permanently installed on a concrete base using 8mm lag screws suitable for concrete, screwed into
drilled implantation holes. Lock washers must be used to prevent the installation lag screws working loose over time. If
the pump has to be mounted on a wooden board, Ø 8 mm hexagonal wood screws must be used combined with lock
washers to prevent the screws working loose over time.
Install the pump under shelter to avoid the control unit being subject to heavy splashing.
The acoustic pressure of Hayward® pumps is less than 70 dBA.
Necessary measures:
Connect the pump to the earth: Never operate the pump unless it is connected to the earth.
Connect the pump with a H07RN-F 3G1,5mm² type cable.
Include a 30 mA differential protection to protect people against electric shocks which may be caused by a breach of
the equipment's electrical insulation.
Include short-circuit protection (the rating is determined according to the value given on the nameplate on the motor).
Include a means of disconnection from the power supply having an opening distance on the contacts of all the poles
ensuring the power supply is completely cut off under the conditions of a category III overvoltage.
WARNING: Wait 5 minutes after having totally disconnected the pump from the power supply before carrying out any
operation on the motor or the connection box: Danger of electric shock which may cause death.
The electric motors fitted to our pumps have thermal protection. This protection reacts in the event of overload or
abnormal temperature rise in the motor winding. This protection automatically resets when the winding temperature drops.
Whatever the type of motor used, if the regulations require it, a magnetic thermal protection must be installed in addition
to the measures described above, which must be calibrated according to the information on the motor's nameplate.
The table on page 169 gives the various characteristics of the motors fitted to our pumps.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward Max-Flo XL VSTD Pump at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward Max-Flo XL VSTD Pump in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 27.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info