USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 11 of 13 EZ-CHEM Rev. B
Calibrating the probes
pH probe
Use pH 7 and pH 4 buffer solutions (check expiry date).
Rinse your probe with tap water before immersing it in the pH 7 solution.
Hold down the button until the Pump Calibration
pH Probe Cal. menu appears, then conrm with .
The Press CAL
B.Solut. 7pH menu appears.
Soak your probe in the pH 7 buffer solution and press .
Wait until the countdown nishes (60 s) and the Quality 100%
B.Solut. 7pH screen appears.
If the quality of the measurement is not 100%, repeat the calibration or replace the probe.
Rinse your probe with tap water before immersing it in the pH 4 solution.
Press the button.
The Press CAL
B.Solut. 4pH menu appears.
Soak your probe in the pH 4 buffer solution and press .
Wait until the countdown nishes (60 s) and the Quality 100%
B. Solut. 4pH screen appears.
If the quality of the measurement is not 100%, repeat the calibration or replace the probe.
ORP Probe (Only with the ORP option)
Use the 465 / 468 mV calibration solution (check expiry date).
Rinse your probe with tap water before immersing it in the 465 / 468 mV solution.
Press when the calibration of the pH probe is nished.
When the following screen appears Pump Calibration
Rx Probe Cal. , conrm with .
The 465 mV
Press CAL menu appears.
Soak your probe in the 465 / 468 mV calibration solution and press .
Wait until the countdown nishes (60 s) and the
Quality 100%
B.Solut. 465 mV screen appears, then conrm with .
If the quality of the measurement is not 100%, repeat the calibration or replace the probe.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward EZ-Chem at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward EZ-Chem in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 59.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info