3.1 HYDROLYSIS 3.2 UV
1.1 Hydrolysis:
Programming of hydrolysis
functions.
1.2 Level: Desired disinfec-
tion level (%).
2.1 Ultraviolet: Programming
of UV system.
2.2 ON status: The UV system
will switch on automatically
when the filtration is on.
2.2 OFF status: The UV system will
never switch on automatically. On
this display, the partial and total
working hours of the lamps can be
verified.
1.2 Cover: Closed cover
detection.
Reduction of chlorine produc-
tion to percentage defined for a
pool with closed cover.
1.2 Boost: Continuous filtration for 24h
at max intensity. Auto return to program-
med filtration mode.
1.3 During the boost period the Redox
control can be deactivated.
Please refer to the section on operation
of the UV lamp for more information
Filtration must be activated in the menu before disinfection can be activated
4. MEASURES / Setpoints
4.1 4.2 4.3 4.1 Measures: Adjustment of setpoints and measuring probes.
4.2 Setpoints for each measurement.
4.3 Setpoints settings: Ideal setpoints for each of the parameters.
The default values are:
pH: 7.3-7.5; redoX: 600-800; Free Chlorine: 0.5-2 ppm;
Conductivity: 1500-2500 ppm for the AQR UV LS.
4.1 MEASURES / pH Calibration
4.5 4.64.4
Metering and control of
the pH of the water
Optional pH control 4.4 Calibration of pH probe:
Recommended every month during
usage season.
4.5 Calibration with buffers (buffer
solutions pH7 / pH10 / neutral):
Follow the instructions in 7 steps
that appear in the display (screen 4.6
corresponds to step 1).
4.7 4.8 4.7 Manual calibration: Allows to adjust the
probes at 1 point (without buffers) – only
recommended to adjust small deviation in
the readings.
4.8 Without removing the probe from the
water, use the plus/minus keys to adjust the
reading so it matches with your reference
value (photometer or other measurement).
pH
The redoX value advises us of the oxidation/reduction potential and is used to determine the level of water sterilization. The parameters or setpoints are the minimum/
maximum accepted redoX levels before the titanium cell is connected/disconnected. Adjusting the ideal redoX level (setpoint) is the last step in the system start up
sequence. To find the optimum redoX levels for your pool follow these steps:
1. Connect the pool filtration system (the salt in the pool must be adequately dissolved).
2. Add chlorine to the pool till a level of 1-1,5 ppm is achieved (approx. 1-1,5 gr/m3 of water). pH levels should be between 7,2 - 7,5.
3. After 30 min. test the free chlorine levels in the pool (manual test kit DPD1) if the free chlorine level is between 0,8 - 1,0 ppm.
Look at the redoX screen and memorize this level as the setpoint to CONNECT/DISCONNECT the electrolysis/hydrolysis cell.
4. The next day check free chlorine levels (manual test kit DPD1) and redoX. Raise/lower setpoint if necessary.
5. Remember to check the redoX set-point every 2-3 month and/or if the water parameters change (pH/temperature/conductivity).
4.2 MEASURES / redoX Calibration
Optional redoX control
Metering and control of the redoX
as check value of the free chlorine.
4.9 Calibration of the redoX probe:
Recommended every 2 months during
usage season.
4.10 Calibration with buffer (buffer
solution 465 mV): Follow the instructions
in 4 steps that appear in the display
(screen 4.11 corresponds to step 1).
4.12 4.13 4.12 Manual calibration: Allows to adjust
the probes at 1 point (without buffers) – only
recommended to adjust small deviation in
the readings.
4.13 Without removing the probe from the
water, use the plus/minus keys to adjust the
reading so it matches with your reference
value (photometer or other measurement).
redoX
4.114.104.9
2.2
2.11.1 1.2 1.3
+
-
+
-
+
-
+
-
+
-
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward AquaRite UV LS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward AquaRite UV LS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 6.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info