pH High - Check Feeder -- If a pH level of 8.1 or higher is detected, check the chemical supply and the feeder for
proper operation
pH Timeout - Check Feeder -- If the unit has been dispensing for more than the selected timeout without reaching the
desired level. Check the chemical supply and the feeder. If both are OK, the timeout may need to be increased. Press
the “+” button to reset the alarm and resume dispensing.
pH Calibration Error -- When using the pH Calibration Wizard and the entered test result was different from the
measured pH level by ± 1.0 or more. The pH probe may need to be cleaned or replaced.
ORP Probe Error -- If the CSM indicates that there is a problem with the ORP probe.
ORP Low - Check Chlor -- If an ORP level of 350mV or less is detected. Check the chlorinator for proper operation.
Check the salt level (> 1.2 g/l)
ORP High - Check Chlor -- If an ORP level of 950mV or higher is detected. Check the chlorinator for proper operation.
ORP High - Chlor Off -- If an ORP level of 950mV or higher is detected and the chlorine feed mode is ORP Auto
Sensing, the chlorinator has been turned off. Check the chlorinator for proper operation.
ORP Timeout -Chlor Off -- If the unit has been chlorinating for more than the selected sanitizer timeout without
reaching the desired level, the chlorinator has been turned off. Press the “+” button to reset the alarm and resume
chlorination.
Ambient Sensor -- If the internal (ambient) sensor is either open or short circuit.
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward Aqua Rite Pro LS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward Aqua Rite Pro LS in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3.96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info