5. ( ) [ALERT]
Toggle to display high temperature alert and then low temperature alert for indoor
thermometer, channel 1, 2, 3remote thermometers respectively and then return to normal
thermo display mode;
Press & hold for 2 seconds at the desired alert temperature display to enter its setting mode,
use [+] / [-] keys to change the settings, press [ ] again to conrm the setting or press on
key for 5 seconds to auto-exit to normal thermo display and conrm the setting;
6. + [UP]
Increase the setting
Press and hold 2 seconds to manually activate radio controlled function; press once again
deactivate radio controlled function;
7. - [DOWN]
Decrease the setting
Toggle Daily Alarm on/off when display shows Alarm mode;
Toggle Alert on/off when display shows corresponding Temperature Alert mode.
And 2 buttons inside battery compartment
8. [°C/°F]
Toggle the temperature unit °C <- -> °F
9. [Reset]
To activate system reset to the main unit during abnormal condition which will reset all
settings back to factory values.
GETTING STARTED
This In-Out thermo clock was designed for easy set up. For best operation, the following steps
are required to be donein the proper sequence.
1. Insert batteries for main unit before doing so for the sensor units.
2. Receiving unit cannot be programmed manually until the wireless remote sensor unit regis-
tration procedure has been completed.
3. Position the remote unit and main unit within effective transmission range, which, in usual
circumstances, is 50 m. Although the remote unit is weather resistant, it should be placed
away from direct sunlight, rain or snow.
BATTERY INSTALLATION FOR MAIN UNIT
1. Remove the battery door;
2. Insert 2 pieces AAA size 1.5V alkaline battery as indicate by the polarity;
3. Close the battery door.
Note: Replace the batteries when the low battery indicator appears on the
top-right corner of the LCD.
BATTERY INSTALLATION FOR REMOTE SENSOR UNIT
1. Lift off the bracket stand of the remote sensor unit by releasing the 2 xing snaps at the
bottom;
2. Use a small type screwdriver to remove the battery cover screws;
3. Insert 2 pieces of AAA size batteries according to the “+” and “-” polarity marks shown in
the battery compartment and then close the battery door.
Remote Sonsor
Bracket Stand
WIRELESS REMOTE SENSOR REGISTRATION PROCEDURE
1. Insert 2 AAA batteries rst to the main unit. The temperature display shows - - . while
the wave icon will keep blinking for 2 minutes indicate the main unit is in sensor searching
mode.
2. In a second step, insert the 2 AAA batteries into the sensor unit. The LED on the front panel
will start ashing at a rate of one time per around 2 seconds indicates channel-1 is in use.
3. While the LED is ashing, press once the [CH] key will change the sensor channel setting
to 2. Keep toggle on [CH] key can change channel setting up to 3. The LED is blinking at a
frequency to indicate the channel setting. i.e. continuous blinks 2 times indicate channel-2 is
selected.
Note: If user does not press any key for 10 seconds, it will exit the channel setting mode
and transmit the RF signal. The main unit will register the temperature reading.
REMOTE CHANNEL AUTO-SCROLLING
This device is equipped with an auto-scroll function. While the auto-scroll function is set, the
unit will automatically cycle to display the temperature of each remote sensor for 6 seconds.
1. To retrieve manually the specic sensor temperature and humidity reading,
press key until desired channel number is displayed.
2. To enable auto-scroll function, use button to toggle channel 1,2,... until auto scroll
icon appears beside the channel indicator.
Lift of this part
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hama EWS170 - 92654 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hama EWS170 - 92654 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 0,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info