564790
8
Zoom out
Zoom in
Previous page
1/34
Next page
8
5.8. Switching off operating status OFF
Procedure:
Press the left key on the operator console until the
information screen appears.
Press the right key (Menu), then move the cursor to
Operating Mode with the two middle keys press the
right key (Select) move the cursor to OFF” operating
mode with the two middle keys press the right key
(Save).
The stove initiates the Cooling down operating status
and can no longer switch to Heating mode by itself, even
if the room temperature falls below the set room
temperature.
During OFF operating status, the operator console and
parts of the control system continue to be supplied with
power. (About 9 Watts per hour).
5.9. Power cut
The control unit has a backup battery so that the data
are retained during a power cut.
A distinction is made between a short power cut and a
long power cut.
Short power cut duration of the power cut shorter than
30 seconds:
Once the electricity supply has been restored, the stove
continues its operation from where it was before the
power cut.
Long power cut duration of the power cut longer than
30 seconds:
Once the electricity supply is restored, the stove
switches to Safety shutdown operating status.
A small amount of flue gas may escape during a power
cut.
5.10. Overheating
If the maximum permitted flue gas temperature is
exceeded, a safety shutdown is initiated and the
following error message is shown on the display:
“Shutdown flue gas temperature in Heating mode too
high”.
The stove cannot restart its heating mode until the error
message has been cleared on the operator console and
the desired operating mode has been reset.
5.11. Low temperature shutdown
If during the Heating mode operating status the stove
cools down below a minimum temperature, a safety
shutdown is initiated and the following error message is
shown on the display:
“Shutdown flue gas temperature heating mode too low”
The stove cannot restart its heating mode until the error
message has been cleared on the operator console and
the desired operating mode has been reset.
6. Description of operator console keys
6.1. Operator console
As can be seen in the figure, the display is divided into
five areas.
The screen title contains the name of the relevant
screen which the operator is currently in. On the same
line, right justified is shown the screen number.
In the Menu/Info area there are four columns with 21
characters each available for the text display.
In the information screens, the operator switches
between individual information screens with keys 2 and
3.
If the operator is in the Selection menu, he will be shown
4 submenu items at the same time. He can choose
between the individual menu items with keys 2 and 3,
with the menu item just selected being indicated with a
black background. If key 3 is pressed again after the
selection of the fourth menu item, the operator will be
taken to further selection items (scrolldown menu).
With key 4 the operator selects a menu item and is then
taken to the relevant submenu or, if a parameter is
selected, to the appropriate window in which the
parameter may be adjusted.
Inactive menu items and information:
Inactive menu items are not shown in the selection
menu.
Nor are inactive measurement values shown by the
relevant configuration on the information screens or in
the values information.
Description of
left key
Description of
right key
Description of
middle keys
Menü- / Infobereich
Tastenbereich
1
2
3
4
Operating mode Heating
Operating status Standby
Target/actual room temp. 20/20°C
Time Date
Tastenbezeichnungen
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn PELLETTO 432.08 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn PELLETTO 432.08 in the language / languages: English as an attachment in your email.

The manual is 3.08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn PELLETTO 432.08

Haas-Sohn PELLETTO 432.08 Usermanual and installation guide - German - 34 pages

Haas-Sohn PELLETTO 432.08 User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info