11.2. General faults
Fault:
Cause:
Correction:
Stove will not ignite
1. The set target room
temperature is lower than the
current room temperature (actual
temperature); the “STANDBY
symbol appears on the display
Increase the target temperature.
2. Storage container is empty
Refill storage container.
3. Excess pressure in the fireplace
system
Open any fireplace vents, remove any dirt
from the fireplace or flue tube
4. Electric ignition is defective
Replace ignition fuse (in the control unit) or
call in the service engineer
5. Electricity supply is interrupted
Put in the mains cable, check fuse (in the
control unit, see Figure 14), check fuse in the
distribution box
6. Error message “OC triggered,
check burner”
Replace fuse F1 in the control unit (T3, 15A)
7. Fuse defective
Replace fuse F3 in the control unit
(T0, 315 A)
No display showing
1. Loose or defective connection
cable between operator console
and control unit
Check plugs and sockets, otherwise call in
the service engineer
Fire burns with a tall
yellow flame;
wood pellets piling up in
the combustion pot
and/or the viewing
panel is excessively
sooty
1. The combustion air supply to
the combustion pot is blocked by
ash deposits.
Turn off the stove and let it cool down.
Remove the combustion pot from its support
and clean the air holes
2. Combustion pot is not correctly
seated
Make sure that the combustion pot is
correctly seated.
3. Poor quality fuel
Use only standard wood pellets. Make sure
that the fuel is dry and cannot absorb any
moisture during storage.
4. Seals on the combustion
chamber door or on the cleaning
covers are defective
Call in the service engineer
5 Flue gas passes or flue tubes
partly blocked with fly ash
Clean flue gas passes and flue tubes
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn HSP2.PREMIUM.17 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn HSP2.PREMIUM.17 in the language / languages: English as an attachment in your email.

The manual is 7.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn HSP2.PREMIUM.17

Haas-Sohn HSP2.PREMIUM.17 Usermanual and installation guide - German - 32 pages

Haas-Sohn HSP2.PREMIUM.17 User Manual - French - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info