811871
30
Zoom out
Zoom in
Previous page
1/36
Next page
GB
26
F014 A. Short-circuit in the temperature
sensor on the input
A. Contact service department
F015 A. Induced draught fan defective
B. Power supply to the fan motor
interrupted
A. Contact service department
B. Check cable - contact service
department
F018 A. Power cut A. Clean burner - Clear error 018
F021 A. Burner dirty
B. Pellet tank empty
C. Downpipe / screw conveyor
blocked
D. Room too airtight required
combustion air cannot flow into
the room
E. Flue gas temperature sensor
defective
F. Screw motor defective
G. Pellet fuel has too low a
calorific value
A. Clean burner
B. Clean burner - fill pellet tank
C. Clean the intake on the screw
conveyor housing with a vacuum
cleaner. Clean burner
D. Clean burner - Ensure
adequate combustion air
E. Flue gas temperature sensor
defective - contact service
department
F. Screw motor defective - contact
service department
G. Clean burner - switch to high
quality pellet type
F022 A. Flue draught too low
B. Flue draught too high
C. Burner dirty
D. Flue tube pipeline too long
(horizontal)
E. Flue gas temperature sensor
defective
A. Measure flue draught - contact
service department
B. Measure flue draught - contact
service department
C. Clean burner
D. Change flue tube pipeline-
contact service department
E. Flue gas temperature sensor
defective - contact service
engineer
F023 A. Flame temperature sensor
defective or not connected
A. Contact service department
F024 A. Flame temperature sensor at
bottom defective or not connected
A. Contact service department
F026 A. Pellet tank empty
B. Burner not lying flush
C. Burner dirty
D. Pellet fuel has too low a
calorific value
E. Downpipe / screw conveyor
blocked
F. Room too airtight required
combustion air cannot flow into
the room
G. Flame temperature sensor
defective
H. Screw motor defective
A. Fill pellet tank
B. Position burner correctly
C. Check burner/ clean burner
D. Switch to high quality pellet
type
E. Clean the intake on the screw
conveyor housing with a vacuum
cleaner.
F. Ensure adequate combustion
air - Connect stove with outside
air
G. Flame temperature sensor
defective - contact service
department
H. Screw motor defective -
contact service department
F027 A. Burner dirty
B. Burner not lying flush
C. Door not sealed properly
A. Clean burner
B. Position burner correctly
C. Check seal on door
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn HSP 6 WT RLU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn HSP 6 WT RLU in the language / languages: English as an attachment in your email.

The manual is 1.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn HSP 6 WT RLU

Haas-Sohn HSP 6 WT RLU User Manual - German - 36 pages

Haas-Sohn HSP 6 WT RLU User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info