7
Picture 4: Windbreak of the air-intake line
The following table is applicable for the
dimensioning of the air intake:
Diameter
Intake tube* Maximum
length* Max. number
of 90° bends
50mm 0.5 m 1
70mm 1 m 1
100mm 3 m 3
*The respective specifications are independently applicable.
The cross-section is to be chosen accordingly when using a
flat duct or the like.
If the dimensions fall below, it can happen,
that the quantity of combustion air is
insufficient. As a result, an increased
formation of slag occurs in the burner tray
and consequently safety shutdowns.
Connection to the power supply:
Connect the stove to the power supply with
the supplied mains cable (see Picture 1).
4. The functional features of the pellet
stove
The functioning method of your pellet stove is
designed for the maintaining of a constant,
comfortable room temperature. The
generation of heat in the stove is therefore
governed automatically according to the
required room temperature set by the
operator (target temperature). Depending on
the difference in temperature between target-
and current room temperature (actual
temperature), in a modular fashion the
controller selects the output or the „Standby“-
operation. As a result, the pellet stove
ensures a greatest possible adaptation of the
burning behavior to the situation in the room
of installation, without constant manual
corrections.
5. Operating states of the pellet stove:
The function of the pellet stove is
characterized by eight operating states:
5.1. Measurement – degree of soiling of
burner tray before the start phase
The start phase begins when the current
room temperature falls below the set target
temperature by 1°C and the stove has cooled
to a temperature of less than 80 C°.
Before the beginning of the start phase, a
measurement of the degree of soiling of the
burner tray is performed.
During this measurement, the components
are switches as follows:
Induced draught blower – ON
Convection air blower – OFF
Screw conveyor – OFF
Ignition – OFF
If the „Burner test“ concludes successfully,
i.e. the burner tray is not or only slightly
soiled, then transition to the operating state
Start Phase takes place.
If the „Measurement – Burner tray soiling“ is
not concluded successfully, i.e. the burner
tray is more heavily soiled than is permitted,
then transition to the operating state Safety
Shutdown takes place and the following error
message appears on the display of the
control unit.
Quit
15:00 24.01.2004
Fault
Shutdown Air Volume
Check burner
Picture 5: Error message
5.2. Start phase
After successfully concluded „Measurement –
Burner tray soiling“, transition to the operating
state Start Phase takes place.
In the „Start phase“, the burner tray is filled
with a precisely defined quantity of fuel and
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn COMPACT-PELLET 310 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn COMPACT-PELLET 310 in the language / languages: English as an attachment in your email.

The manual is 3.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn COMPACT-PELLET 310

Haas-Sohn COMPACT-PELLET 310 User Manual - German - 43 pages

Haas-Sohn COMPACT-PELLET 310 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info