10
Press the left key on the control unit until the
information page appears.
Press right key (menu), then with the two
middle keys, set the cursor to Mode – press
right key (select) – with the two middle keys,
set the cursor to Mode „OFF“ – press right
key (Save).
The stove initiates the operating state Cooling
and can no longer start the heating operation
automatically, not even with undershooting of
the set room temperature.
During the operating state OFF, the control
unit and parts of the controller continue to be
supplied with power (approx. 9 Watt per
hour).
5.10. Power failure
The control unit has a buffer battery, so that
the data are retained during the power failure.
Differentiation is made between a short-term
and a long-term power failure.
Short-term power failure – duration of the
power failure shorter than 30 seconds:
After the power supply is returned, the stove
resumes its operation from that point in which
it was before the power failure.
Long-term power failure – duration of the
power failure longer than 30 seconds
After the power supply is returned, the stove
switches to the operating state Safety
Shutdown.
With a power failure, a small quantity of flue
gas can possibly escape.
5.11. Overheating
If the maximum permissible waste-gas
temperature is exceeded, then a safety
shutdown is initiated and the following error
message appears on the display:
„Shutdown waste-gas temperature heating
operation too high“
The stove can only resume its heating
operation when the error message on the
control unit has been acknowledged and the
required operating mode has been set again.
5.12. Low-temperature shutdown
If, during the operating state Heating, the
stove cools below a minimum temperature,
then a safety shutdown is initiated and the
following error message is indicated on the
display:
„Shutdown waste-gas temperature heating
operation too low“
The stove can only resume its heating
operation when the error message on the
control unit has been acknowledged and the
required operating mode has been set again.
6. Description of keys on the control unit
6.1. Control unit
As shown in the picture, the display is divided
into five areas.
The page label contains the name of the
respective page in which the operator is
presently in. In the same row, the page
number is indicated right-aligned.
In the menu- / Info area, there are four rows
each with 21 characters available for the text
display.
In the information pages, the operator
switches between the individual information
pages with the keys 2 and 3.
If the operator is in the selection menu, then
at the same time he is shown 4 submenu
items. With the keys 2 and 3, he can select
between the individual menu items, whereby
the menu item currently selected is
highlighted with a black bar. If after the
selection of the 4th menu item, the key 3 is
Page label Page No.
Description
Left key Description
Right key
Description
Middle keys
1 2
3
4
Mode Heating
Operating state Standby
Room taget/actual 20/20°C
Time Date
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn COMPACT-PELLET 309 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn COMPACT-PELLET 309 in the language / languages: English as an attachment in your email.

The manual is 3.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn COMPACT-PELLET 309

Haas-Sohn COMPACT-PELLET 309 User Manual - German - 43 pages

Haas-Sohn COMPACT-PELLET 309 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info