COOLING SYSTEM ( TIG 208 ONLY)
NEVER USE YOUR MACHINE WITHOUT COOLING LIQUID.
FAILURE to adhere to this may result in damage to the pump in the cooling system.
The system is designed for cooling the TIG torch « liquid cooled ». It operates:
Simultaneously with the fan.
Only in TIG mode (the pump will start even with an « air cooled » torch).
Fill the tank with an engine coolant (or similar) up to the mark, taking care not to over-fill (1.25 L capacity).
REMOTE CONTROL
The remote control operates in TIG and MMA mode.
Connector technology
The Tig 207FV and 208 are equipped with a female socket for a remote control. The specific 7 point male
plug (GYS product ref.045699) enables connection to a manual remote control (RC) or foot pedal (PEd).
For the cabling lay out, see the diagram below.
Connecting remote/pedal
1- Power up the machine
2- Plug the pedal/remote control to the connecting socket on the machine.
3- The screen will flash and display « No » (Nothing),
4- Select the type of control by turning the intensity adjustment knob:
« No » (Nothing) / « RC » (Remote Control) / « PEd » (Pedal)
5- Turn the knob until the desired selecton is reached, and after 2 seconds the display will freeze on the
chosen selection.
NB: In case of error, unplug the remote control, ( « No » will be displayed) and re-start the connection
process.
Remark: You will be asked to specify the remote connected each time the machine is powered up.
Functions
Manual remote control (
GYS product ref.045675)
:
The remote control enables the variation of current from minimum intensity (DC : 5A / AC : 10 / MMA : 10A)
to an intensity defined by the user.
In this configuration, all modes and functions of the machine are accessible and can be set.
Pedal (
GYS product ref.045682)
:
In all modes excluding « Spot » mode, the pedal control enables variation of the current from the minimum
intensity (DC : 5A / AC : 10) to an intensity definied by the user.
In TIG mode, the machine will only operate in two-stage welding (2T mode). The upslope and downslope
are not automatic, and are controlled by the User with the foot pedal.
In « Spot » mode, the pedal control replaces the torch trigger (the pedal position has no effect on the
current).
DUTY CYCLE
The welding unit describes an output characteristic of a "constant current". The duty cycles following the
norm EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below :
D : Switch contact
C : Earth
B : Cursor
A : + 5V
Nb : The Potentiometer value must be 10 K
Ref.045699
TIG 207 (230V) /208
AC
DC
X% @
I max
X% @
I max
X% @
I max
13% 200A 21% 160A 21% 160A
60%
95A
60%
95A
60%
95A
100%
80A
100%
80A
100%
80A
TIG 207 (110V)
AC
DC
X% @
I max
X% @
I max
X% @
I max
20%
160A
20%
160A
21%
110A
60%
90A
60%
90A
60%
90A
100%
75A
100%
80A
100%
75A
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys TIG 208 AC-DC HF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys TIG 208 AC-DC HF in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info