M1 - T1 & M3 - T3 GYS AUTO
EN
DESCRIPTION
Thank you for your choosing this product. In order to get the best from your purchase, please read with care the fol-
lowing instructions:
The M1 GYS auto, T1 GYS auto, M3 GYS auto and T3 GYS auto are «synergic» semi-automatic welding units on wheels,
ventilated for welding (MIG or MAG). They are recommended to weld steel, stainless steel, aluminium and for “MIG Bra-
zing” of high-tensile strength steels with CuSi and CuAl wires (ideal for car body repairs). Their adjustment is quick and
easy with their « synergic wire speed » function. The T1 and T3 GYS auto work on 3-phase 400V or on 230V/400V - 3
phase for the T1 GYS auto DV and T3 GYS auto DV. he M1 and M3 GYS auto work on single phase 230V or on 208/240V
for the M1 208/240V and M3 208/240V.
ELECTRICITY SUPPLY
The absorbed current (I1rms) is indicated on the device, for its maximum setting. Check that the power supply and its
protection (fuse and/or circuit breaker) are compatible with the current needed by the machine. The device must be
positioned so that the socket is always accessible.
- The M1 and M3 GYS AUTO have to be connected to a single phase power supply - 230V earthed power supply with a
circuit breaker 16A and 1 differential 30mA.
- The T1 GYS auto, T3 GYS auto, T1 GYS auto DV and T3 GYS auto DV have to be connected to a 3-phase power supply
- 400V earthed power supply with a a circuit breaker 16A and 1 differential 30mA. Do not use with extension leads with
a cable cross section below 2.5mm².
- Only for T1 GYS auto DV and T3 GYS auto DV: 3-phase power supply - 230V, WARNING: this device is pre-assembled
at the factory on 3-phase 400V. If your electrical installation is on 3-phase 230V, amend the connections on the terminal
block inside the product. This operation must be done by a skilled and qualied person. Please see electrical diagram
230V located inside the product. The power supply must be protected by a 16A circuit breaker and 1 differential 30mA.<
(See electrical diagram at the end of the manual)
- For the M1 GYS auto 208/240V and M3 GYS auto 208/240V: Single phase power supply 208V, WARNING: this device
is pre-assembled at the factory on single phase 240V. If your electrical installation is single phase 208V, amend the
connections on the terminal block inside the product. This operation must be done by a skilled and qualied person.
Please see electrical diagram 208V located inside the product. The power supply must be protected by a circuit breaker
16A and 1 differential 30mA.< (See electrical diagram at the end of the manual)
CONTROLS AND FEATURES (FIG 1 & 2)
1- switch On-Off
2- 7 positions power adjustement switch : aloows adjust-
ment of the welding voltage at the generator output. The
adjustment of the output voltage is proportional to the
thickness of the material to weld. (g 6)
3- welding settings adjustement keyboard (manual or
automatic mode)
4- European standard torch coupling
5- spool on gun coupling command
6- torch support
7- supply cable (2m M1GYS AUTO, 3m T1GYS, 6m T3GYS
and M3 GYS).
8- out earth cable for T1GYS and M1GYS AUTO, earth
cable with a 200A clamp for T3GYS and M3GYS.
9- gas bottles support (max 1 bottle 4m³ for M1GYS
AUTO and max 2 bottles 4m³ for T1GYS, T3GYS,
M3GYS).
10- fastening chain for bottles
11- reel sopport 200/300 mm
12- solenoid valve torch 1
13- torch cable support
T3GYS :
14- reel support 200 mm
15- solenoid valve torch 2
16- solenoid vavle for spool gun
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys T3 GYS AUTO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys T3 GYS AUTO in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info