665727
9
Zoom out
Zoom in
Previous page
1/33
Next page
9
Two or three times a year, remove the steel case and remove dust with compressed air. The electrical
connections (with an insulated tool) and the insulations check must be checked by a qualified person.
Regularly control the state of the cord. If the power cable is damaged, it must be replaced by the
manufacturer, its after sales service or a qualified technician to avoid any danger.
ADVICES
Respect welding polarities and currents indicated on the electrode packaging.
Remove the electrode from the electrode holder when you do not use it.
Leave the ventilation grill free to allow in/out air circulation.
SECURITY
Arc welding can be dangerous and leads serious injury, may fatal. Protect yourself and protect
the others.
Respect the following warnings:
Arc rays
Protect yourself thanks to a welding helmet in compliance with EN175 equiped with filters in
compliance with EN 169 or EN 379. Inform and protect by the same means any people in
the welding environment.
Rain, steam,
humidity
Use your welding unit in a clean/dry environment (pollution factor ≤ 3), on a flat surface, and
more than one meter from the workpiece. Do not use in rain or snow.
Electric shocks
This device must only be used with a power supply with earth. Do not touch the parts under
high voltage. Check that the power supply is suitable for this unit.
Falls
Do not underestimate the weight of the apparatus. Do not carry it over people or objects. Do
not drop it. Do not set it down heavily
Burns
Wear protective or fire-proof clothing (overalls, jeans).
Use welder gloves and a fire-proof apron.
Protect the others by installing a non flammable protection wall, or prevent the others from
looking at the arc and have them keep a sufficient distance.
Fire risks
Avoid all flammable products in the working area. Do not work near flammable gas.
Fumes
Do not inhale gas or welding fumes. If welding indoors, ventilate the area well and/or use
local fume extraction system.
Additional
Precautions
Any welding operation undertaken in :
-in environments with increased risk of electric shocks,
-in confined spaces and poorly ventilated rooms,
-in the presence of flammable or explosive materials, must be evaluated in advance by an
“Expert supervisor” and must always be carried out in the presence of other people trained
to intervene in case of emergency.
Technic
al protection measures MUST BE taken as described in the TECHNICAL
SPECIFICATION "IEC 62081".
Welding in raised positions is forbidden unless safety platforms are used.
People wearing Pacemakers are advised to see their doctor before using this device.
Do not use the welding unit to unfreeze pipes.
Handle gas bottles with care - there is increased danger if the bottle or its valve are damaged.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys PROGYS 200A PFC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys PROGYS 200A PFC in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info