PHM output connection
6
Depending on the desired charging current:
1. choose a cable
(not supplied)
with the appropriate cross-section
(see recommendations table below)
.
2. Choose the corresponding cable lug
(25, 35, 50, 70 mm² supplied).
3. crimp with an appropriate crimping tool.
Recommendations on the maximum length of cables in metres, depending on their cross-section and current intensity.
I max (A)
100 120 140 160 180 200 220 240 250 260 280 300 320 340 360 380 400
Cross-section
(mm²)
25 15 12 11 9,2 8,2 7,4 
35 21 17 15 13 11 10 9,4 8,6 8,2 
50 29 25 21 18 16 15 13 12 12 11 11 9,8 9,2
70 41 34 29 26 23 21 19 17 16 16 15 14 13 12 11 11 10
Values given for the use of fully copper-plated cables.
7Shrink the heat-shrinkable tubing provided.
8Pass the red cable through an input cable gland + (1) of the housing.
And the black cable in an inlet cable gland - (2) of the housing.
9Screw the cables with the screws provided in the bag (red wire at the
top / black wire at the bottom)
Tighten the screws well
(5 Nm)
.
10 Tighten the cable gland.
11 Replace the product cover.
11
POWER HUB MODULE EN
Translation of the original instructions
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys Power Hub Module at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys Power Hub Module in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info