786857
10
Zoom out
Zoom in
Previous page
1/40
Next page
PREPARATION
Before wiring the product, make sure that all chargers are switched o and that no batte-
ries are connected (risk of short circuit).
1Unscrew the cover (5) of the PHM (6 screws).
Connection inlet PHM
2
Remove the clamps from the power cables of the GYSFLASH chargers.
If the charging cables are too long
(2.5 or 5 m depending on the GYSFLASH)
:
- Cut the cables to the desired length.
- choose the appropriate lug
(10, 16 or 25 mm² depending on the GYSFLASH cable(s))
.
-
crimp with appropriate pliers.
- Shrink tubing to the wall
(use 25 mm of the 200 mm tubing heat-shrinkable supplied).
The length of the cable must not be less than 1 m.
3Pass the red cable through an input cable gland + (1) of the housing.
And the black cable in an inlet cable gland - (2) of the housing.
4Screw the cables to the corresponding plate with the screws provided in
the bag (red cable to Cu plate + above / black cable to Cu plate - below).
Tighten the screws well
(5 Nm)
.
5Tighten the cable glands used.
1
2
10
POWER HUB MODULE EN
Translation of the original instructions
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys Power Hub Module at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys Power Hub Module in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info