NEOPULSE 400
EN
CONNECTIONS AND RECOMMENDATIONS
The connection between the welding machine and the wire feeder must be done while the power supply is off.
Open the access panel and pass the interconnection cable
through the circular opening at the back of the wire feeder.
Lock the interconnection cable on the wire feeder’s panel by
twisting it clockwise by 1/4.
Lock the support using the screw supplied with the connection
cable.
Pass the interconnection cable through the trolley.
Lock the interconnection cable on the trolley by twisting it
clockwise by 1/4.
Lock the support using the screw supplied with the connection
cable.
POWER SUPPLY – STARTING UP
This equipment is tted with a 32A / 5 pin socket (3P+N+PE) which must be connected to a three-phase 400V (50 - 60 Hz) power supply tted with
four wires and one earthed neutral.
The absorbed effective current (I1eff) is displayed on the machine, for optimal use. Check that the power supply and its protection (fuse and/or
circuit breaker) are compatible with the current required by the machine. In some countries, it may be necessary to change the plug to allow the use
at maximum settings.
The machine ie designed to work on a 400V +/- 15% power supply. • The device turns into protection mode if the power supply tension below 330V
RMS or over 469V RMS.. (To indicate this default, the wire feeder’s screen displays an error code, check the instruction manual).
• The start is done via an on / off switch (6 - FIG 1) set to I, and the stop is done by switiching it to O. Warning ! Never disconnect the power supply
when the machine is on.
• Cooling fan management : This welding machine features an intellingent cooling fan system, in order to minimise noise. The fans will adjust their
speed depending on the current use and ambient temperature. They may be off in MIG mode.
CONNECTION TO A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements :
- The voltage must be AC, always superior to 400Vac ±15%, and the peak voltage below 700V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as several generators generate high voltage peaks that can damage these machines.
USE WITH EXTENSION CABLES
All extension cables must have an adequate size and section, relative to the machine’s voltage .
Use an extension that complies with national safety regulations.
Current input Extension selection (<45m)
400V 6 mm²
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys NEOPULSE 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys NEOPULSE 400 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 5,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info