665817
12
Zoom out
Zoom in
Previous page
1/62
Next page
12
MAGYS 400-4 / 400 GR / 500 GR / 500 WS
EN
REEL AND TORCH ASSEMBLY (FIG. 3)
Position the reel on to the support taking care of the pin (1). To use with 5kg (Ø200mm) wire reels requires use of
reel adaptor (ref. 042889).
• Adjust the reel break (2) to avoid the reel movement tangling the wire when welding stops. Then tighten the plastic
screw (3) rmly.
• For the rst use :
- Release the xing screw of the wire guide (5)
- Place the rollers, and tighten the screws (6).
- Place the wire guide (7) as close as possible to the roller but without touching it, then tighten the xing screw.
To select the adjustment of the drive rollers (8), bend the wire where it comes out of the nozzle to stop it, and then
start the motor. Tighten the knob whilst pressing the trigger until the wire starts to move. The setting is correct when
the guide roller slides over the wire, even when it is blocked at the end of the torch.
NOTE: When the trigger is pulled and without any contact detected within 4s, the MAGYS will automatically switch to
the ‘fast forward’ mode until the trigger is released. There is no gas during this operation.
WARNING: The ‘fast forward’ mode use current in the wire; avoid any contact with any metallic part around.
GAS COUPLING
Fit the regulator/owmeter to the gas bottle, and then t the gas pipe to the connector (see (10), FIG-2 for MAGYS
400-4). To avoid gas leaks, use the collars provided in the accessories box.
LIQUID COOLING (MAGYS 500 WS) (FIG-2) & THERMAL PROTECTION
Connect the red and blue wire of the connecting harness from the generator (11) to the separate wire feeder (see WS-
4L/W5S-4L user manual)
Fill the tank (12) up to its maximum (5,5L). The CORAGARD CS330 cooling liquid (or equivalent), recommended
by GYS, must be used (more information in the website: www.aqua-concept-gmbh.eu). The use of any other cooling
liquid, and especially the standard automobile liquid, can lead by electrolysis effect, to the accumulation of dumps in the
cooling system, damaging it and even more by blocking the circuit.
Any damage caused to the machine by the use of another cooling liquid will not be taken under warranty.
The MAGYS 500 WS is not recommended to be used by an air cooled torch.
If anyway you want to use an air cooled torch, a by-pass is supplied with the unit. Connect it between
the red and blue cables. If you don’t respect this rule, the pump will be damaged, and the repair will not
be taken under warranty.
MAGYS 500 WS: NEVER USE YOUR UNIT WITHOUT COOLING LIQUID
when the pump is working. Ensure liquid is at least minimum level (gauge at back of machine)
Failure to adhere to this may result in irreparable damage to the cooling system, and machine.
• Always respect the basic rules of welding.
• Do not block/cover the ventilation holes of the machine.
• Leave the device plugged in after welding to allow proper cooling down.
• Thermal protection: The LED(8) switches on when the unit is on safety mode. The cooling time (forced ventilation) is
by cycle of 10 minutes for the 400-4 and 20 minutes (forced ventilation + pump) for the MAGYS 400 GR/500 GR/500
WS depending on the external temperature.
• Ventilation: the fan is only active during the welding and the cooling cycles.
DUTY CYCLE & WELDING ENVIRONMENT IN USE
• The welding unit describes an output characteristic of "constant current" type. The duty cycles following the standard
EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below:
X / 60974-1 @ 40°C (T cycle = 10 min) I max 60% (T cycle = 10 min) 100% (T cycle = 10 min)
Magys 400-4 / 400 GR 50% @ 350 A 320 A 260 A
Magys 500 GR / 500 WS 50% @ 450 A 410 A 320 A
Note : The machines’ duty cycle has been tested at room temperature (40°C) and has been determined by simulation.
• These are Class-A devices. They are designed to be used in an industrial or professional environment. In a different en-
vironment, it can be difcult to ensure electromagnetic compatibility, due to conducted disturbances as well as radiation.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys MAGYS 400-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys MAGYS 400-4 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info