GYSMI 80P 130P 160P 200P
MADE IN FRANCE
EN
All welders should take the following precautions in order to minimise exposure to the electromagnetic elds (EMF)
generated by the welding circuit::
– position the welding cables together – if possible, attach them;
– keep your head and torso as far as possible from the welding circuit;
– never wrap the cables around your body;
– never position your body between the welding cables. Hold both welding cables on the same side of your body;
– connect the earth clamp as close as possible to the area being welded;
– do not work too close to, do not lean and do not sit on the welding machine
– do not weld when you’re carrying the welding machine or its wire feeder.
People wearing pacemakers are advised to consult their doctor before using this device.
Exposure to electromagnetic elds while welding may have other health effects which are not yet
known.
RECOMMENDATIONS TO ASSESS THE WELDING AREA AND WELDING INSTALLATION
Overview
The user is responsible for installing and using the arc welding equipment in accordance with the manufacturer’s
instructions. If electromagnetic disturbances are detected, it is be the responsibility of the user of the arc welding
equipment to resolve the situation with the manufacturer’s technical assistance. In some cases this remedial action
may be as simple as earthing the welding circuit (see note). In other cases, it may be necessary to construct an
electromagnetic shield around the welding power source and around the entire piece by tting input lters. In all cases,
electromagnetic interferences must be reduced until they are no longer bothersome.
Welding area assessment
Before installing the machine, the user must evaluate the possible electromagnetic problems that may arise in the area
where the installation is planned, in particular, it should consider the following:
a. Other cables, control cables, telephone cables: above, below and besides the device;
b. Radio/TV transmitters and receptors,
c. Computers and other control equipments,
d. Critical safety equipments such as industrial machines’ emergency controls.
e. The health and safety of the people who are close to the machine, e.g. people who wear a pacemaker, a hearing aid,
etc ...
f. Equipment used to calibrate and measure,
g. The immunity of the other equipments installed in the welding area or near the welding machine. The user will have
to make sure that the devices in the same room are compatible with each other. This may require additional precautions.
h. The time of day during which the unit must operate;
The surface of the area to be considered around the device depends on the the building’s structure and other activities
that take place there. The area taken in consideration can be larger than the limits determined by the companies.
Welding area assessment
Besides the welding area, the assessment of the arc welding systems installation itself can be used to identify and
resolve cases of disturbances. The assessment of emissions must include in-situ measurements as specied in Article 10
of CISPR 11: 2009. In situ measurements can also be used to conrm the effectiveness of mitigation measures.
RECOMMENDATION ON METHODS OF ELECTROMAGNETIC EMISSIONS REDUCTION
a. National power grid: The arc welding machine must be connected to the national power grid in accordance with
the manufacturer’s recommendation. If interferences occur, it may be necessary to take additional preventive measures
such as the ltering of the power supply network. Consideration should be given to shielding the power supply cable
in a metal conduit. It is necessary to ensure the shielding’s electrical continuity along the cable’s entire length. The
shielding should be connected to the welding machine to ensure good electrical contact between the metal conduct and
the casing of the welding machine.
b. Maintenance of the arc welding equipment: The arc welding machine should be be submitted to a routine
maintenance check according to the manufacturers recommendations. All accesses, service doors and covers should be
closed and properly locked when the arc welding equipment is on.. The arc welding equipment must not be modied
in any way, except for the changes and settings outlined in the manufacturer’s instructions. The spark gap of the arc
start and arc stabilization devices must be adjusted and maintained according to the manufacturers recommendations.
c. Welding cables: Cables must be as short as possible, close to each other and close to the ground, if not on the
groud.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys GYSMI 200P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys GYSMI 200P in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info