625737
8
Zoom out
Zoom in
Previous page
1/52
Next page
8
GYSFLASH 40-12 FV
Courbe de charge (IU
0
I
0
U)
Test Test Charge Absorption Floating
New charge
cycle
Shorted cell
Recovery
Sulphation
Test
Desulphation
I
U
1 2 3 4 5 6 7 8 9
10
Refresh
Recovery
Phase I Phase U0 Phase I0
Phase U
U=Ucharge
U=Uoating
U=Urecovery
max.
T
recovery
I=Icharge
I=Irefresh
Trefresh
max.
T
desulfat
Tch
U=Urefresh
1
Analyse de la batterie
2
Récupération des éléments endommagés suite à une décharge profonde prolongée
3
Test batterie sulfatée
4
Désulfatation/Récupération de la batterie
5
Vérication de la récupération de la batterie
6
Charge de la batterie à 80%
7
Charge de la batterie à 100%
8
Rafraichissement des cellules de la batterie
9
Charge de maintenance
10
Recommence un cycle de charge pour un maintien des performances = Entretien
Pour enregistrer et valider les nouveaux réglages, sélectionner «ADVANCED MENU» | save? Yes»
Appuyer sur le bouton « MODE » pour sortir du menu « Conguration ».
MODE
PROTECTIONS
Cet appareil est protégé contre les courts-circuits, inversions de polarité. Il dispose d’un système anti-étincelle qui évite toutes étin-
celles lors du branchement du chargeur sur la batterie. Sans tension aux pinces, il ne délivre pas de courant par sécurité.
Ce chargeur est protégé contre les erreurs de manipulation par un fusible interne 80A (ref. 054653).
ANOMALIES, CAUSES, REMÈDES
ANOMALIES CAUSES REMÈDES
1
Afchage clignotant :
« #erreur (+)<-->(-) »
+ signal sonore
Inversion de polarité sur les pinces Brancher la pince rouge au (+) et la pince noire au (-) de la batterie.
2
Afchage clignotant :
« #erreur U>Umax »
+ signal sonore
Tension de batterie trop élevée Chargeur non adapté (ex : batterie 24V au lieu de 12V).
3
Afchage clignotant :
« #erreur batterie »
+ signal sonore
Batterie est en court-circuit ou endommagée. Batterie à remplacer.
Batterie non connectée ou pinces en court-circuit Vérier le branchement des pinces de charge.
Batterie 6V connectée Chargeur non adapté.
FR
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys GYSFLASH 40-12 FV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys GYSFLASH 40-12 FV in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 2,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info