Emergency Action
Apply the first aid adequate to the injury and get qualified
medical assistance as quickly as possible. Protect the injured
person from more accidents and calm him/her down.
For the sake of eventual accident, in accordance with DIN
13164, a workplace has to be fitted with a first-aid kit. It is
essential to replace any used material in the first-aid kit
immediately after it has been used. If you seek help, state
the following pieces of information:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)
Assigned Use
These devices can be used to charge lead batteries typically
used in motor vehicles (petrol and diesel fuel). The type of
electrolyte may be selected freely
The design of them includes double insulation and
therefore, no earthing wire is required. They are marked
with a visible symbol on the body.
While the battery is being charged (cf. Section “Charging
Time”), the operation is carried out with slowly falling
charging current
Unfit for gel batteries!
It is recommended to check continuously that the battery
charger power id adapted to the capacity of battery to be
charged. A charge too slow may demand too much time
for charging a battery. On the other hand, a powerful unit
may damage the battery.
Overload protection (pic. 2 and 3)
They have overload protection (a safety provision to protect
the battery charger from the effects of wrong connections or
overloading).
The overload protection device is a device to protect the
battery charger against failures and mishandling. It secures
safety of the entire circuit. If the device is enabled, it is
necessary to check to see whether all the instructions have
been observed
Important Notice! Replacement fuses, the resistance
values of which are different from the plate values, may
cause material and personal damage
The fuses replacement should not be done unless the
mains cable is unplugged. We shall not be held liable, not
even for the repair if the procedure is contrary to the
requirement
Fig 1 Fig 2
A. Fuse A. Fuse
B. Fuse
Residual Electrical Hazards
1. Direct electrical contact
Defective cable one plug may cause an electrical
shock injury.
Have the defective cables and plugs replaced at a
specialist’s. Use the unit on a connection equipped
with a current protection (FI).
2. Indirect electrical contact
A risk of injury by conductive parts with open or
defective parts of the unit
Disconnect the unit from the source of power to
maintain it. Operate with a current protection only.
3. Insufficient Lighting of Workplace
Insufficient lighting always present a high safety
risk.
Always provide for sufficient lighting when working
with the unit.
Disposal
Disposal instructions are illustrated in the form of pictograms
on the device or packaging. Description of the pictograms is
given in "Identification" chapter.
Disposal of transport packaging
Packaging protects the device against damage during
transport. Packaging materials are usually selected according
to their effect on environment and disposal methods and can
therefore be recycled.
Returning of the packaging back to circulation saves resources
and costs for packaging disposal.
Parts of the packaging (e.g. foil, styropor) may be dangerous
for children. Risk of suffocation!
Keep these parts of the packaging out of reach of children and
dispose as soon as possible.
Handling requirements
The operating staff must carefully read the Operating
Instructions before using the appliance.
Qualification
Apart from the detailed instruction by a professional no special
qualification is necessary for using the appliance.
Minimum age
Only persons over 16 years of age can work with the
appliance. An exception includes youngsters if they work
within their professional education the purpose of which is to
obtain knowledge supervised by a trainer.
Training
Using the appliance only requires corresponding training by a
professional or following of the Operating Instructions. No
special training is necessary.
Technical data
Connector: 230 V/50-60 Hz
Charging voltage at
start:
12/24 V
Charging current: 200 Amp.
Charging arithmetic
current:
160 Amp.
Starting current 0 V: 1500 Amp.
Starting current 1,5 V: 1000 Amp.
Max mains power: 30 kW
Min. protection: 16 Amp.
Rated capacity: 36/2500 AH
Battery start: 120-200 Ah without subpena
240 Ah mit with subpoena
Weight: 65 kg
Transportation and Storage
If putting the unit away for a prolonged storage, it should be
cleaned thoroughly.
Securing the device in a clean, dry place
Protect the unit from weather effects with a tarpaulin, carton
etc.
Operation (pic. 1, 4)
pic. 4:
1: Beginning of charging
2: In the course of charging
3: End of Chargign
4: Empty
5: Half-charged
6: Fully charged
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude V 1200 T 85072 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude V 1200 T 85072 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info