Failures - Causes - Removal
ATTENTION: MAKE SURE YOU ALWAYS FIRST CHECK THE FUSES AGAINST OVERLOADING!
Failure Cause Removal
Engine does not start
No system voltage
Blocked runner blade of the pump
Check the voltage
Use a screwdriver to turn the armature shaft through
the fan cover (loosen the stuck mechanical padding)
Pump does not suck
No foot valve or it is untight, blocked
Foot valve not in water
Pump housing without water
Suction lift too big
Air holes in the suction tube
Connectors are not tightened, pump draws air, no
bleeding at the pump
Install or clean the foot valve
Plunge the admission valve to water
Fill the pump housing
Check the suction lift
Check the suction tube tightness
Connect it again, carefully according to instructions in
the “Putting into operation“ chapter!
Insufficient amount of
pumped water
Suction lift too big
Tube filter of the foot valve is dirty
Water level quickly dropping
Check the suction lift
Clean the tube filter
Put the foot valve lower
Clean the pump and replace quickly worn out parts.
Thermal switch does not
switch the pump off
Thermal protection has switched the pump off
due to overheating.
No electric current.
Bits (e.g. small stones) have settled in the suction
nozzle.
Let the appliance cool down!
Dismantle and clean the pump, prevent sucking of
foreign materials.
Inspection and maintenance
Except for the below-described cases, the pump needs to be sent to the customer service for repair if necessary.
Safety instructions for inspections and maintenance
Before any work and maintenance of the pump, it is always necessary to interrupt current supply (pull the plug out of socket) and
make sure the pump is not able to start spontaneously.
Only an appliance subject to regular maintenance and care can be a satisfactory assistant. Insufficient maintenance and care can
lead to unpredictable injuries and wounds.
Inspection and maintenance plan
Time interval Description Other details
As necessary and
depending on the
pollution level
Foot valve to be cleaned
Foot valve
working to be
inspected (D)
33
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude HWA 1200 IC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude HWA 1200 IC in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info