Electric safety:
DANGER! Electric shock!
Risk of injury by electric shock!
Pull the plug out of socket before fill of the pump, after
switching it off, at repair removal and before
maintenance.
Operate the appliance on connectors with an earth-
leakage circuit-breaker (RCD)!
Please consult with an electrician.
Information on the type label must correspond to information
of the electric network.
Protect the cable against high temperatures, oil and sharp
edges.
General instructions:
Before using the pump, always execute a visual inspection
to detect any damage of the pump, especially the line cord
and plug.
A damaged pump must not be used.
In case of any fault, have the pump checked in a service
department of GUDE or at an authorised electrician.
Do not expose the pump to rain and do not use it in a moist or
wet environment.
To prevent the pump from running dry, please make sure the
end of the suction hose was always plunged in the pumped
medium.
Fill the pump with the pumped liquid until it overflows before
each starting!
When the pump is used as a home pumping station, local
regulations of a water company need to be observed.
Moreover, provision of the DIN 1988 standard must be
obeyed.
Behaviour in emergency
Provide first aid of a corresponding nature and level of injury
and call qualified medical help as soon as possible.
Rest the injured person in peace and in a manner he/she did
not sustain any other injury.
Appliance use as designed
The pump is solely designed to pump clear water to supply
water to a house, garden, court and agriculture. If the
generally binding regulations and provision of these
Instructions are not observed the producer cannot be held
liable for any damage.
Residual risks and protective measures
Electric residual risks
Threat Description Protective measures
direct electric
contact
electric shock earth-leakage circuit-breaker
indirect
electric
contact
electric shock
through
pumped
medium
earth-leakage circuit-breaker
Disposal
The disposal instructions are based on icons placed on the
package or appliance. The description of individual meanings
can be found in the “Marking on appliance“ chapter.
Handling requirements
The operating staff must carefully read and understand the
Operating Instructions before using the appliance.
Qualification
Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age
Persons over 16 years of age can only work on the appliance.
An exception includes use by youngsters if the appliance is
used under supervision of trainer within occupational
preparation and its use serves to reach the necessary
knowledge.
Training
Appropriate training executed by a competent person,
knowing the Operating Instructions, is only necessary for
using of the appliance. No special training is necessary.
Technical data
HWA 1200 IC
Supply voltage 230 V / 50 Hz
P1 engine power 1200 W/P1
Max. suction lift 8 m
Max. amount pumped 3,800 l an hour
Max. head of delivery 50 m
Discharge connector 1“
Suction connector 1’’
Protection type IP 44
Water temperature 35 °C
Weight app. 12,4 kg
Product No. 94207
Transport and storing
When storing the appliance for a winter period it is
necessary to make sure there is no water in the appliance as
frost could be a cause for appliance damage.
At each transport and carrying, the appliance must be
disconnected from electric current source!
Assembly and first putting into operation
Filter and sludge screen
At pumping water with sand contents, the pump needs to be
operated with a sludge filter (available as accessory) for the
suction connector. Sand entering the mechanical seal
(propeller shaft engine - pump) would damage the pump! That
would mean, even during the guarantee time, your own fault
and the guarantee does not relate to such failures.
Safety instructions for first putting the pump into
operation
Attention: the pump must never run dry.
Do not use the pump for pumping drinking water!
The user is responsible to other persons as far as pump
(pumping station, etc.) operation is concerned.
Operate on connectors fitted with an earth-leakage
circuit-breaker only!
Before putting the appliance into operation, a competent
electrician must check that the appliance disposes of the
required electric safety elements.
Wiring is done to a socket. Check the voltage. Technical data
specified on the label must correspond with the electrical
network voltage.
If you use the pump for small lakes, wells, etc. and pumping
stations you must follow appropriate standards of the country in
which the pump is used.
Electrical pumps used outdoor must be fitted with a rubber
H07RNF-type electric cable corresponding to DIN 57282 or DIN
57245 standards.
When the pump is in operation, there must be no people
or animals in the pumped liquid (e.g. in pools, cellars,
etc.)
The temperature of the pumped liquid must not exceed +35
°C. If you use an extension cable it must be solely of rubber,
the H07RNF type, corresponding to DIN 57282 or DIN
57245 standards. Never touch, lift or carry a pump
connected to electrical network with a cable. Make sure
there is no water or moisture in the connecting socket and
the plug was protected against moisture.
31
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude HWA 1200 IC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude HWA 1200 IC in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info