Technical specifications:
Rated thermal load Weight
Nozzle Operating pressure
Gas category Consumption
EU DECLARATION OF CONFORMITY
We,
Güde GmbH & Co. KG
Birkichstrasse 6
D-74549 Wolpertshausen
Deutschland,
herewith declare that the following appliance complies with
the appropriate basic safety and health requirements of the
EU Directives based on its design and type, as brought
into circulation by us.
In case of alternation of the machine, not agreed upon
by us, this declaration will lose its validity.
Machine description: GT 4200 Z
Article No.: #17304
Applicable EU Directives:
2009/142/EG
Applicable harmonised standards:
DIN 3372
Date/authorised signature: 10.06.2010
Title of signatory: Managing Director
Mr Arnold
Technical documentation: J. Bürkle FBL; QS
Guarantee
The guarantee solely covers inadequacies caused by
material defect or manufacturing defect. Original payment
voucher with the sales date needs to be submitted for any
claim in the guarantee period. The guarantee does not
cover any unauthorised use such as appliance
overloading, use of violence, damage as a result of any
unauthorised interference or caused by foreign items.
Failing to follow the operating and assembly instructions
and common wear are also not included in the guarantee.
Residual risks and protective measures
THERMAL RESIDUAL RISKS
Burns, chilblains
When operating the appliance, the heat shield and
safety screen are very hot and can cause serious
burns when touched.
You must not touch the safety screen and the heat shield.
EXPOSURE TO MATERIALS AND OTHER
SUBSTANCES
Contact, inhalation
Inhalation of propane or butane may be harmful to
health.
Make sure all the connections are tight and use the
appliance outdoors only or in well ventilated rooms.
A great amount of oxygen is consumed when
operating the heater, which may lead to the lack of
oxygen in small rooms.
To be used in well ventilated rooms only! Operating the
appliance in living rooms and bedrooms is prohibited.
Fire or explosion
The highest risk of fire and explosion is near highly
flammable substances.
Keep at least a distance of 2 m on all sides. Do not
operate the appliance near flammable substances.
Do not use the appliance for dry textiles or other
flammable substances.
Behaviour in case of emergency
In case of accident, first aid kit must always be available in
the place of your work in accordance with DIN 13164.
Material taken out of the first aid kit needs to be
supplemented right away.
If help is needed, please provide the following details:
Place of accident
Accident nature
Number of injured persons
Injury type
Provide necessary first aid treatment corresponding to the
injury nature and seek qualified medical help as soon as
possible. Protect the injured person against other injuries
and calm him/her down.
Use as designated
Caution!
THE APPLIANCE MUST NOT BE USED FOR HEAT
LIVING SPACES IN RESIDENTIAL BUILDINGS. LOCAL
PROVISIONS MUST BE FOLLOWED IN PUBLIC
BUILDINGS.
To be used outdoors only.
The appliance may be used in the following countries:
Germany, Austria, Switzerland.
Please keep to the local conditions applicable to
installation: e.g. for Germany (TRF: Technical
regulations for liquids).
The socket heater has exclusively been designed for
heating sites (fabrics), etc. Any other use is considered a
use in conflict with the designation. The manufacturer will
not be liable for any consequential damage.
The use as designated provisions also include:
Following all instructions from the operation
manual and the supplied operation instructions
and
Complying with all cleaning and treatment
conditions specified by the manufacturer.
The socket heater must not be used:
To heat enclosed or residential spaces
(residential buildings) or for operation purposes
in these spaces;
Near flammable materials (e.g. paper, building
materials);
In places where volatile materials (e.g. petrol,
solvents, chemicals) are kept or where an
explosive atmosphere may be produced;
After any voluntary design change of the socket
heater;
In case of wrong or unacceptable connection to
the source of gas
In places not ventilated sufficiently.
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GT 4200 Z 17304 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GT 4200 Z 17304 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 3,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info