629293
13
Zoom out
Zoom in
Previous page
1/48
Next page
Installation & Programming Guide — 13
The Control Panel is pre-programmed as follows:-
Zone 1 EnEx Point This zone is configured as a final exit point for full
(Entry Exit) set, part set 1/ 2 and it can be ommited.
Zone 2 Entry Route E.R. This zone is configured for an alarm zone with walk
(walk through) through if the final exit point is activated. This zone
will also give entry time start in Part 1 and 2 set. The
zone can also be ommited.
Zone 3 Alarm Zone This zone is configured to be an alarm zone in full
(Part 1 set alarm)
set and Part Set 1, and is ommitable.
Zone 4 Alarm Zone, This zone is configured to be an alarm zone in full
(Part 2 set alarm)
set and Part Set 2, and is ommitable.
Zone 5 Alarm zone This zone gives an alarm in full set and is ommitable.
Zone 6 Alarm zone This zone gives an alarm in full set and is ommitable.
Zone 7 Alarm zone This zone gives an alarm in full set and is ommitable.
Zone 8 Alarm zone This zone gives an alarm in full set and is ommitable.
Zones 9 - 32 Off No attributes
Bell Time 15 minutes
Full Set entry 30 seconds
Part Set exit 15 seconds
Full Set exit 20 seconds
Output 1 Detector Reset
Output 2 Detector Latch/Bell Follow (depending on variant)
User Codes 0101
0202
0303
0404 etc.
to
1414
Engineer Code
9999
Default ConfigurationsDefault Configurations
Default ConfigurationsDefault Configurations
Default Configurations
Installation & Programming
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Guardall WINDSOR SERIES 300i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Guardall WINDSOR SERIES 300i in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info