PX/QX/RX Version 4.20 User Manual – Issue B
- 5 -
Introduction
The PX Electronic Intruder Alarm System is designed to provide secure protection for the installation.
The system comprises a main control panel, normally located out of sight in a secure area, and at
least one keypad. The panel has a wide range of features, which are programmed by the engineer on
installation, to suit the security requirements of the particular installation. Some of the features may be
reprogrammed, edited, or viewed as required by an authorised user.
Feature RX16i QX32i PX48i PX80i PX500 PX250
HS
Max. Panel Users 32 32 50 100 200 200
Max. Access Users
1000 1000 1000 1000
Areas 4 8 8 16 32 16
Set Groups
8 8 16 32 16
Sub systems
4 4 8 16 8
Max Keypads 4 8 8 16 32 16
Access Modules
32 32 32 32
Audio Modules 2 4 8 16 32 16
Radio Modules 2 2 4 8 16 8
Max. Transmitters 16 16 24 40 128 128
Tel Numbers 8 8 8 8 8 8
Schedules 2 4 32 32 32 32
Holidays
14 14 14 14 20
Event Log Size 250 500 1000 1000 1000 2000
Access Log Size
1000 1000 1000 1000
Event Log
The event log will record all events, for example, user log-on times and user numbers, keypad
numbers, setting and unsetting times, alterations made to programmed settings, fault conditions, etc.
When the event log is full, the oldest event will be automatically removed when the next event occurs.
All log events are date and time stamped and may be viewed, or printed if a printer is fitted to the
system.
Areas & Set Groups
For protection purposes, the premises may be divided into a number of areas. Individual areas may
be grouped together into a setting group (Not RX16i) which provides the user with a convenient way
of setting and unsetting more than one area at the same time. The installation company engineer will
have configured your system for the appropriate number of areas and groups to comply with your
specific security requirements. Where more than one group is incorporated in the system, a group
can be configured by the installation engineer as a common group. A common group will
automatically set if all other areas of the system are set and will automatically unset if any one of the
other areas is unset. The RX16i variant does not include the set group feature. If using a RX16i then
all references to set groups throughout this manual should be interpreted as areas.
Circuits
Each detector or sensor in the installation is allocated a unique circuit number. The installation
engineer will have programmed each circuit to respond in a certain way when the circuit is activated,
when the area is set and unset. The way in which the circuit is programmed to respond will depend on
the type of circuit and its location and purpose. If a circuit is faulty, the alarm response may be turned
off by an authorised user. This process is referred to as bypassing.
User, Set group and Circuit Identification
Each user, set group, circuit, concentrator and access control module can be programmed with a text
description.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Guardall QX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Guardall QX in the language / languages: English as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Guardall QX

Guardall QX Installation Guide - English - 46 pages

Guardall QX User Manual - Dutch - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info