4
Automatic flushing (72 Hours) activate/deactivate
Maintenance, see Fig. [14] and [15].
Shut off water supply
Inspect and clean all components and replace if necessary
A nearly discharged battery is indicated by 2 beep sounds
after pressing the transmitter button. Flushing is then initiated.
An empty battery is indicated by a beep sound every minute.
Flushing is no longer initiated.
Replacement parts, see fold-out page I (* = special
accessory).
Disposal note
Dispose of batteries in accordance with national
regulations!
The flow volume can be changed within 20 seconds of
flushing (if necessary) by pressing the button again. The
selected flush setting is stored if the button is not pressed
again within 20 seconds of flushing.
1. Activate registration mode by pressing button (A), see
Fig. [10].
Indicator lamp (B) displays:
██
2. Repeat pressing and holding button (A).
Indicator lamp displays:
▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌_____▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌_____████
3. When ████ appears, release button.
4. Button pressed for the first time (within 2 seconds)
Indicator lamp displays:
██ ██ ██ ██ Automatic flushing activated
Button pressed for the second time (within 2 seconds)
Indicator lamp displays:
██████ ██████ Automatic flushing deactivated
Each press of the button switches between the two states.
The selected setting is stored if the button is not pressed
again within 10 seconds of flushing.
Fault/ Cause / Remedy
Fault Cause Remedial action
No flushing after the radio
transmitter has been actuated
Water supply interrupted - Open isolating valve in cistern
Radio transmitter not registered - Registering a radio transmitter
Batteries in radio receiver unit are empty
(a beep is sounded every minute)
- Replace batteries
Servo motor defective (no rotation) - Replace radio receiver unit
Radio transmitter is too far away - Install radio transmitter within
transmission range (10 m)
Battery in radio transmitter is discharged - Replace battery in radio transmitter
Water flowing continuously Outlet valve not closing - Repair or replace outlet valve, see
instructions for cistern
Servo motor defective (lever does not
return to end position)
- Replace radio receiver unit
Undesired flushing Adjacent radio transmitter unintentionally
registered
- Delete all radio transmitters and re-
register the correct radio transmitters
Automatic flushing activated - Deactivate automatic flushing
Flow volume too low Servo motor defective (incomplete
rotation)
- Replace radio receiver unit
Residual flow rate too high - Push residual flow slider downwards
Flow rate in cistern too low - Turn float of filler valve further upwards
2 beeps sound after the radio
transmitter has been actuated
Batteries in radio receiver unit are nearly
discharged
- Replace batteries
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe 39141 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe 39141 in the language / languages: English, German, Dutch, Polish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info