3
GB
Applications
The radio receiver unit triggers flushing by using a radio
transmitter.
Additionally, flushing can be triggered by manual actuation.
Manual actuation requires a WC cover plate for the pneumatic
outlet valve (not included in the delivery specification).
For actuation via radio control, use radio transmitter order
no. 38 758 or 39 142 + button (see replacement parts fold-out
page I). As an alternative to GROHE radio transmitters, the
product can also be used with radio transmitters made by
Hewi, Keuco, Lehnen, Normbau, Pressalit, AMS, Deubad,
Erlau FRELU and FSB.
Installation is an option with cistern GD2 with pneumatic outlet
valve and filler valve on the left side, see fold-out page I
Fig. [1].
Safety information
Perform installation in frost-proof rooms only.
Use only genuine replacement parts and accessories. Using
other parts will void the warranty and CE marking.
Technical Data
Voltage supply: 4 x 1,5 V battery, type LR-20
Reception frequency: 868.4 MHz
Flow volume (3 - 6/9 l adjustable): 6 l
Small flow volume: 3 l
(radio transmitters with 2 buttons only)
Blocking time after a flushing: 5 s
Automatic flushing (72 Hours): Inactive
Approval and conformity
Conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Observe installation dimensions, see Fig. [2].
New installation: Cut off inspection chamber flush with
tiles, see Fig. [3a].
Conversion: Dismantle actuation plate, see Fig. [3b].
Prepare cistern, see fold-out pages I and II, Figs. [4] to [6].
Replace existing hose with included hose with elbow, see
Fig. [7].
Attach lift rod to overflow pipe of outlet valve, see Fig. [8].
Insert batteries (not included in the delivery specification),
see Fig. [9].
Making settings, see chapter Making settings.
Install radio receiver unit, see Fig. [11] and [12].
Open water supply, see Fig. [12].
Install actuation plate, see Fig. [13].
Making settings
Registering a radio transmitter
A maximum of 30 radio transmitters may be registered.
When registering a radio transmitter, make sure that no other
radio transmitters are being operated at the same time.
Deleting a radio transmitter
Set flow volume
This product conforms to the requirements of the
relevant EU directives.
1. Activate registration mode by pressing button (A), see
Fig. [10].
Indicator lamp (B) displays:
██
2. Within 30 seconds, press the transmitter button (C) for
triggering flushing.
Indicator lamp displays:
██ ██ ██
The actuated radio transmitter is registered. Registration
mode is terminated.
Further radio transmitters are registered as described above.
1. Press and hold button (A), see Fig. [10].
Indicator lamp (B) displays:
██ ______________________________██
2. Release button.
All registered radio transmitters have been deleted.
1. Activate registration mode by pressing button (A), see
Fig. [10].
Indicator lamp (B) displays:
██
2. Repeat pressing and holding button (A).
Indicator lamp displays:
▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌___
3. When___ appears, release button.
Flow volume setting mode is activated. Flow volume is
selected by pressing the button.
4. Button pressed for the first time (within 2 seconds)
Indicator lamp displays:
██ ██ ██ Flow volume 3 l
Button pressed for the second time (within 2 seconds)
Indicator lamp displays:
██ ██ ██ ██ Flow volume: 4 l
Button pressed for the third time (within 2 seconds)
Indicator lamp displays:
██ ██ ██ ██ ██ Flow volume: 5 l
Button pressed for the fourth time (within 2 seconds)
Indicator lamp displays:
██ ██ ██ ██ ██ ██ Flow volume: 6 l
Button pressed for the fifth time (within 2 seconds)
Indicator lamp displays:
██ ██ ██ ██ ██ ██ ██ Flow volume: 9 l
After the group with 7 flashing signals, the routine starts
from the beginning.
The flow volume is selected by refraining from pressing the
button within 2 seconds after the desired flow volume is
signalled.
One flush is performed at the set volume with the signal
flashing once more.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe 39141 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe 39141 in the language / languages: English, German, Dutch, Polish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info